Radium-228 results

MS0490008 , South Winona Water Association

9 samples have been analysed for Radium-228 at South Winona Water Association.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Radium-228 result

All 9 samples analysed for this analyte are listed below, newest first. No date range is applied.

9 Radium-228 results from the 9 samples listed here: 0 detected, 9 not detected. Those samples also carried 23 results for other analytes, which are on the full results page.

Radium-228 results for South Winona Water Association, from the 9 samples analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Dec 14, 2015 09:30
Sampling point
TF104 Treatment Facility TF104
Sample type
Routine
Lab sample
201512180232
Laboratory
Radiation Safety Engineering
Not detected below 0.26 pci/l Minimum Reporting Level , sample collected Dec 14, 2015 09:30, sampling point TF104 Radium-228 4030 EPA method 904 Oct 1, 2015 – Dec 31, 2015
Collected
Dec 14, 2015 09:05
Sampling point
TF103 Treatment Facility TF103
Sample type
Routine
Lab sample
201512180231
Laboratory
Radiation Safety Engineering
Not detected below 0.25 pci/l Minimum Reporting Level , sample collected Dec 14, 2015 09:05, sampling point TF103 Radium-228 4030 EPA method 904 Oct 1, 2015 – Dec 31, 2015
Collected
Aug 27, 2015 14:30
Sampling point
TF104 Treatment Facility TF104
Sample type
Routine
Lab sample
201509020219
Laboratory
Radiation Safety Engineering
Not detected below 0.32 pci/l Minimum Reporting Level , sample collected Aug 27, 2015 14:30, sampling point TF104 Radium-228 4030 EPA method 904 Jul 1, 2015 – Sep 30, 2015
Collected
Aug 27, 2015 14:00
Sampling point
TF103 Treatment Facility TF103
Sample type
Routine
Lab sample
201509020218
Laboratory
Radiation Safety Engineering
Not detected below 0.32 pci/l Minimum Reporting Level , sample collected Aug 27, 2015 14:00, sampling point TF103 Radium-228 4030 EPA method 904 Jul 1, 2015 – Sep 30, 2015
Collected
Jul 17, 2012 13:30
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
201211140288
Laboratory
Radiation Safety Engineering
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected Jul 17, 2012 13:30, sampling point TF080 Radium-228 4030 EPA method 904.0 Jul 1, 2012 – Sep 30, 2012
Collected
Jul 16, 2012 14:00
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
120717-116
Laboratory
Radiation Safety Engineering
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected Jul 16, 2012 14:00, sampling point TF080 Radium-228 4030 EPA method 904.0 Jul 1, 2012 – Sep 30, 2012
Collected
Apr 23, 2012 14:00
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
120424-150
Laboratory
Radiation Safety Engineering
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected Apr 23, 2012 14:00, sampling point TF080 Radium-228 4030 EPA method 904.0 Apr 1, 2012 – Jun 30, 2012
Collected
Feb 14, 2012 15:27
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
120215-107
Laboratory
Radiation Safety Engineering
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected Feb 14, 2012 15:27, sampling point TF080 Radium-228 4030 EPA method 904.0 Jan 1, 2012 – Mar 31, 2012
Collected
Dec 12, 2011 13:30
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
111213-155
Laboratory
Radiation Safety Engineering
Not detected below 0.28 pci/l Minimum Reporting Level , sample collected Dec 12, 2011 13:30, sampling point TF080 Radium-228 4030 EPA method 904.0 Oct 1, 2011 – Dec 31, 2011

Routine (9).