Chemical and radiological sample results
MS0510009 , City of Newton
20 of the 56 analytes this system has been tested for have been detected at least once, across 350 samples on record.
The other 36 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 350 samples on record, detections range from October 15, 2003 to June 30, 2026. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 261 of 261 results | Jun 17, 2004 | Sep 14, 2023 |
| Lead 1030 | Inorganic Chemical | 203 of 261 results | Jun 17, 2004 | Sep 14, 2023 |
| TTHM 2950 | Organic Chemical | 18 of 18 results | Jul 19, 2004 | Nov 19, 2025 |
| Chloroform 2941 | Organic Chemical | 13 of 13 results | Sep 26, 2007 | Nov 19, 2025 |
| Bromodichloromethane 2943 | Organic Chemical | 13 of 13 results | Sep 26, 2007 | Nov 19, 2025 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 13 of 18 results | Aug 28, 2007 | Aug 12, 2025 |
| Dibromochloromethane 2944 | Organic Chemical | 12 of 13 results | Sep 26, 2007 | Nov 19, 2025 |
| Fluoride 1025 | Inorganic Chemical | 11 of 11 results | Oct 15, 2003 | Jun 30, 2026 |
| Barium 1010 | Inorganic Chemical | 10 of 10 results | Oct 15, 2003 | Mar 17, 2025 |
| Dichloroacetic Acid 2451 | Organic Chemical | 8 of 12 results | Jun 14, 2010 | Aug 12, 2025 |
| Trichloroacetic Acid 2452 | Organic Chemical | 8 of 12 results | Jun 14, 2010 | Aug 12, 2025 |
| Nickel 1036 | Inorganic Chemical | 8 of 10 results | Mar 10, 2004 | Mar 17, 2025 |
| Chromium 1020 | Inorganic Chemical | 5 of 10 results | Oct 15, 2003 | May 6, 2019 |
| Gross Alpha Particle Activity 4109 | Radionuclide | 4 of 4 results | Sep 6, 2011 | Apr 2, 2012 |
| Sodium 1052 | Inorganic Chemical | 3 of 3 results | Sep 18, 2019 | Feb 24, 2025 |
| Dibromoacetic Acid 2454 | Organic Chemical | 2 of 12 results | Aug 19, 2013 | Jul 11, 2016 |
| Sulfate 1055 | Inorganic Chemical | 2 of 2 results | Oct 15, 2003 | Mar 10, 2004 |
| Arsenic 1005 | Inorganic Chemical | 1 of 10 results | Apr 4, 2005 | Apr 4, 2005 |
| Cadmium 1015 | Inorganic Chemical | 1 of 10 results | Apr 4, 2005 | Apr 4, 2005 |
| Selenium 1045 | Inorganic Chemical | 1 of 10 results | Apr 4, 2005 | Apr 4, 2005 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 131–140 of 350 samples, newest first — collected September 6, 2011 to May 1, 2013. The summary above covers all 350.
28 results from the 10 samples listed here: 8 detected, 20 not detected. Across the whole record it is 597 of 1,022. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 1, 2013 13:51, sampling point TF080 | Arsenic 1005 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
| 0.0277 mg/l , sample collected May 1, 2013 13:51, sampling point TF080 | Barium 1010 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 1, 2013 13:51, sampling point TF080 | Cadmium 1015 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
| 0.0014 mg/l , sample collected May 1, 2013 13:51, sampling point TF080 | Chromium 1020 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
| 0.633 mg/l , sample collected May 1, 2013 13:51, sampling point TF080 | Fluoride 1025 EPA method 300.0 | Jan 1, 2011 – Dec 31, 2013 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 1, 2013 13:51, sampling point TF080 | Mercury 1035 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
| 0.0017 mg/l , sample collected May 1, 2013 13:51, sampling point TF080 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected May 1, 2013 13:51, sampling point TF080 | Selenium 1045 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 1, 2013 13:51, sampling point TF080 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 1, 2013 13:51, sampling point TF080 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 1, 2013 13:51, sampling point TF080 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2011 – Dec 31, 2013 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 6, 2013 15:20, sampling point TF080 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Mar 6, 2013 15:20, sampling point TF080 | Nitrate 1040 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Mar 6, 2013 15:20, sampling point TF080 | Nitrite 1041 EPA method 353.2 | Jan 1, 2013 – Dec 31, 2013 |
|
||
| Not detected below 15 ug/l Minimum Reporting Level , sample collected Sep 24, 2012 15:15, sampling point TF080 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2011 – Dec 31, 2013 |
|
||
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Apr 2, 2012 14:36, sampling point TF080 | Radium-228 4030 EPA method 904 | Apr 1, 2012 – Jun 30, 2012 |
| 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Apr 2, 2012 14:36, sampling point TF080 | Gross Alpha Particle Activity 4109 EPA method 00-02 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Apr 2, 2012 14:36, sampling point TF080 | Combined Uranium 4006 EPA method 200.8 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 5, 2012 15:13, sampling point TF080 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2012 – Dec 31, 2012 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Mar 5, 2012 15:13, sampling point TF080 | Nitrate 1040 EPA method 353.2 | Jan 1, 2012 – Dec 31, 2012 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Mar 5, 2012 15:13, sampling point TF080 | Nitrite 1041 EPA method 353.2 | Jan 1, 2012 – Dec 31, 2012 |
|
||
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Jan 23, 2012 13:33, sampling point TF080 | Radium-228 4030 EPA method 904 | Jan 1, 2012 – Mar 31, 2012 |
| 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jan 23, 2012 13:33, sampling point TF080 | Gross Alpha Particle Activity 4109 EPA method 00-02 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 23, 2012 13:33, sampling point TF080 | Combined Uranium 4006 EPA method 200.8 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Dec 15, 2011 13:30, sampling point TF080 | Radium-228 4030 EPA method 904 | Oct 1, 2011 – Dec 31, 2011 |
| 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Dec 15, 2011 13:30, sampling point TF080 | Gross Alpha Particle Activity 4109 EPA method 00-02 | Oct 1, 2011 – Dec 31, 2011 |
|
||
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Sep 6, 2011 14:00, sampling point TF080 | Radium-228 4030 EPA method 904 | Jul 1, 2011 – Sep 30, 2011 |
| 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 6, 2011 14:00, sampling point TF080 | Gross Alpha Particle Activity 4109 EPA method 00-02 | Jul 1, 2011 – Sep 30, 2011 |
-
- Collected
- May 1, 2013 13:51
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 130502-038IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Barium 1010 EPA method 200.8
- Result
- 0.0277 mg/l
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Chromium 1020 EPA method 200.8
- Result
- 0.0014 mg/l
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Fluoride 1025 EPA method 300.0
- Result
- 0.633 mg/l
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Nickel 1036 EPA method 200.8
- Result
- 0.0017 mg/l
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0025 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
- Collected
- Mar 6, 2013 15:20
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 130307-032NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2013 – Dec 31, 2013
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Sep 24, 2012 15:15
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 120925-006CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 15 ug/l Minimum Reporting Level
-
- Collected
- Apr 2, 2012 14:36
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 120403-025
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
-
Gross Alpha Particle Activity 4109 EPA method 00-02
- Result
- 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Apr 2, 2012 14:36
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 120403-025RU
- Laboratory
- MSDH Lab
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Mar 5, 2012 15:13
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 120306-044NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2012 – Dec 31, 2012
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method 353.2
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Jan 23, 2012 13:33
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 120124-027
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
-
Gross Alpha Particle Activity 4109 EPA method 00-02
- Result
- 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Jan 23, 2012 13:33
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 120124-027RU
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Combined Uranium 4006 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Dec 15, 2011 13:30
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 111216-074
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2011 – Dec 31, 2011
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
-
Gross Alpha Particle Activity 4109 EPA method 00-02
- Result
- 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Sep 6, 2011 14:00
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 110907-004
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jul 1, 2011 – Sep 30, 2011
-
Radium-228 4030 EPA method 904
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
-
Gross Alpha Particle Activity 4109 EPA method 00-02
- Result
- 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
Routine (10).