Radium-226 results
MS0520004 , Macon Electric & Water Dept.
16 samples have been analysed for Radium-226 at Macon Electric & Water Dept..
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Radium-226 result
The table below lists 1–10 of 16 samples, newest first — collected December 6, 2011 to April 3, 2012.
10 Radium-226 results from the 10 samples listed here: 2 detected, 8 not detected. Those samples also carried 30 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.2 pci/l Minimum Reporting Level , sample collected Apr 3, 2012 15:45, sampling point TF104 | Radium-226 4020 EPA method 903.1 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 0.2 pci/l Minimum Reporting Level , sample collected Apr 3, 2012 15:30, sampling point TF103 | Radium-226 4020 EPA method 903.1 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 0.3 pci/l Minimum Reporting Level , sample collected Apr 3, 2012 13:15, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| 0.4 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Apr 3, 2012 14:00, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Apr 1, 2012 – Jun 30, 2012 |
|
||
| Not detected below 0.2 pci/l Minimum Reporting Level , sample collected Jan 24, 2012 14:00, sampling point TF104 | Radium-226 4020 EPA method 903.1 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| Not detected below 0.2 pci/l Minimum Reporting Level , sample collected Jan 24, 2012 15:15, sampling point TF103 | Radium-226 4020 EPA method 903.1 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| Not detected below 0.3 pci/l Minimum Reporting Level , sample collected Jan 24, 2012 14:30, sampling point TF102 | Radium-226 4020 EPA method 903.1 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| 0.4 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jan 24, 2012 13:15, sampling point TF101 | Radium-226 4020 EPA method 903.1 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| Not detected below 0.2 pci/l Minimum Reporting Level , sample collected Dec 6, 2011 15:00, sampling point TF104 | Radium-226 4020 EPA method 903.1 | Oct 1, 2011 – Dec 31, 2011 |
|
||
| Not detected below 0.2 pci/l Minimum Reporting Level , sample collected Dec 6, 2011 13:30, sampling point TF103 | Radium-226 4020 EPA method 903.1 | Oct 1, 2011 – Dec 31, 2011 |
-
- Collected
- Apr 3, 2012 15:45
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 120404-003
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.2 pci/l Minimum Reporting Level
-
- Collected
- Apr 3, 2012 15:30
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 120404-002
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.2 pci/l Minimum Reporting Level
-
- Collected
- Apr 3, 2012 13:15
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120404-005
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.3 pci/l Minimum Reporting Level
-
- Collected
- Apr 3, 2012 14:00
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120404-004
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Apr 1, 2012 – Jun 30, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- 0.4 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Jan 24, 2012 14:00
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 120125-017
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.2 pci/l Minimum Reporting Level
-
- Collected
- Jan 24, 2012 15:15
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 120125-016
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.2 pci/l Minimum Reporting Level
-
- Collected
- Jan 24, 2012 14:30
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 120125-012
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.3 pci/l Minimum Reporting Level
-
- Collected
- Jan 24, 2012 13:15
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 120125-011
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
Radium-226 4020 EPA method 903.1
- Result
- 0.4 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Dec 6, 2011 15:00
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 111207-094
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2011 – Dec 31, 2011
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.2 pci/l Minimum Reporting Level
-
- Collected
- Dec 6, 2011 13:30
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 111207-093
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2011 – Dec 31, 2011
-
Radium-226 4020 EPA method 903.1
- Result
- Not detected below 0.2 pci/l Minimum Reporting Level
Routine (10).