Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Chemical and radiological sample results

MS0520004 , Macon Electric & Water Dept.

21 of the 57 analytes this system has been tested for have been detected at least once, across 385 samples on record.

The other 36 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 385 samples on record, detections range from November 5, 2003 to March 18, 2025. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Macon Electric & Water Dept., with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 120 of 120 results Sep 11, 2007 Sep 29, 2023
Lead 1030 Inorganic Chemical 44 of 120 results Sep 11, 2007 Sep 14, 2023
Barium 1010 Inorganic Chemical 40 of 40 results Nov 5, 2003 Mar 18, 2025
Fluoride 1025 Inorganic Chemical 40 of 40 results Nov 5, 2003 Mar 18, 2025
Nickel 1036 Inorganic Chemical 22 of 40 results Mar 24, 2004 Mar 18, 2025
Arsenic 1005 Inorganic Chemical 18 of 40 results Mar 24, 2004 Mar 18, 2025
Chromium 1020 Inorganic Chemical 16 of 40 results Mar 24, 2004 Mar 7, 2016
Gross Alpha Particle Activity 4109 Radionuclide 16 of 16 results Sep 6, 2011 Apr 3, 2012
Sodium 1052 Inorganic Chemical 12 of 12 results Sep 17, 2019 Feb 25, 2025
Selenium 1045 Inorganic Chemical 10 of 40 results Mar 24, 2004 Jan 20, 2010
Combined Radium (-226 & -228) 4010 Radionuclide 4 of 16 results Sep 16, 2011 Apr 3, 2012
Radium-226 4020 Radionuclide 4 of 16 results Sep 16, 2011 Apr 3, 2012
Sulfate 1055 Inorganic Chemical 4 of 8 results Nov 5, 2003 Nov 5, 2003
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 3 of 19 results Jun 24, 2010 Dec 8, 2016
TTHM 2950 Organic Chemical 3 of 19 results Aug 30, 2007 Sep 3, 2013
Monochloroacetic Acid 2450 Organic Chemical 1 of 14 results Dec 8, 2016 Dec 8, 2016
Dibromoacetic Acid 2454 Organic Chemical 1 of 14 results Sep 3, 2013 Sep 3, 2013
Bromoform 2942 Organic Chemical 1 of 14 results Sep 3, 2013 Sep 3, 2013
Dibromochloromethane 2944 Organic Chemical 1 of 14 results Sep 3, 2013 Sep 3, 2013
Nitrite 1041 Inorganic Chemical 1 of 88 results Mar 4, 2013 Mar 4, 2013
Cadmium 1015 Inorganic Chemical 1 of 40 results Mar 20, 2006 Mar 20, 2006

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 91–100 of 385 samples, newest first — collected August 7, 2020 to November 10, 2020. The summary above covers all 385.

24 results from the 10 samples listed here: 12 detected, 12 not detected. Across the whole record it is 362 of 1,836. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for Macon Electric & Water Dept., every result from 91 to 100 of 385 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Nov 10, 2020 15:21
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
201111-005HA
Laboratory
MSDH Lab
Not detected below 0.002 mg/l Minimum Reporting Level , sample collected Nov 10, 2020 15:21, sampling point MRT000 Monochloroacetic Acid 2450 EPA method 552.2 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Nov 10, 2020 15:21, sampling point MRT000 Dichloroacetic Acid 2451 EPA method 552.2 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Nov 10, 2020 15:21, sampling point MRT000 Trichloroacetic Acid 2452 EPA method 552.2 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Nov 10, 2020 15:21, sampling point MRT000 Monobromoacetic Acid 2453 EPA method 552.2 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Nov 10, 2020 15:21, sampling point MRT000 Dibromoacetic Acid 2454 EPA method 552.2 Not recorded
Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Nov 10, 2020 15:21, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Not recorded
Collected
Aug 7, 2020 08:15
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-039PB
Laboratory
MSDH Lab
0.1731 mg/l , sample collected Aug 7, 2020 08:15, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
0.0007 mg/l , sample collected Aug 7, 2020 08:15, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Aug 7, 2020 06:40
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-038PB
Laboratory
MSDH Lab
0.0073 mg/l , sample collected Aug 7, 2020 06:40, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
0.0006 mg/l , sample collected Aug 7, 2020 06:40, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Aug 7, 2020 08:00
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-037PB
Laboratory
MSDH Lab
0.0807 mg/l , sample collected Aug 7, 2020 08:00, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 7, 2020 08:00, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Aug 7, 2020 05:30
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-036PB
Laboratory
MSDH Lab
0.0056 mg/l , sample collected Aug 7, 2020 05:30, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 7, 2020 05:30, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Aug 7, 2020 05:30
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-035PB
Laboratory
MSDH Lab
0.1412 mg/l , sample collected Aug 7, 2020 05:30, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 7, 2020 05:30, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Aug 7, 2020 06:45
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-034PB
Laboratory
MSDH Lab
0.0391 mg/l , sample collected Aug 7, 2020 06:45, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
0.0007 mg/l , sample collected Aug 7, 2020 06:45, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Aug 7, 2020 04:30
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-033PB
Laboratory
MSDH Lab
0.0034 mg/l , sample collected Aug 7, 2020 04:30, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 7, 2020 04:30, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Aug 7, 2020 05:00
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-032PB
Laboratory
MSDH Lab
0.007 mg/l , sample collected Aug 7, 2020 05:00, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 7, 2020 05:00, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Collected
Aug 7, 2020 07:30
Sampling point
DS000 Distribution
Sample type
Routine
Lab sample
200810-031PB
Laboratory
MSDH Lab
0.1339 mg/l , sample collected Aug 7, 2020 07:30, sampling point DS000 Copper, Free 1022 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 7, 2020 07:30, sampling point DS000 Lead 1030 EPA method 200.8 Jan 1, 2018 – Dec 31, 2020

Routine (10).