This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Copper, Free results
MS0530021 , Town of Sturgis
150 samples have been analysed for Copper, Free at Town of Sturgis.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Copper, Free result
The table below lists 11–20 of 150 samples, newest first — collected July 29, 2020 to July 30, 2020.
10 Copper, Free results from the 10 samples listed here: 10 detected, 0 not detected. Those samples also carried 10 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.0128 mg/l , sample collected Jul 30, 2020 04:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0197 mg/l , sample collected Jul 30, 2020 05:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0177 mg/l , sample collected Jul 29, 2020 08:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0366 mg/l , sample collected Jul 29, 2020 11:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0176 mg/l , sample collected Jul 29, 2020 07:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0359 mg/l , sample collected Jul 29, 2020 12:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0942 mg/l , sample collected Jul 29, 2020 06:13, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0342 mg/l , sample collected Jul 29, 2020 06:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.0729 mg/l , sample collected Jul 29, 2020 06:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.019 mg/l , sample collected Jul 29, 2020 05:45, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
-
- Collected
- Jul 30, 2020 04:30
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-029PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0128 mg/l
-
- Collected
- Jul 30, 2020 05:30
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-026PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0197 mg/l
-
- Collected
- Jul 29, 2020 08:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-035PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0177 mg/l
-
- Collected
- Jul 29, 2020 11:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-034PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0366 mg/l
-
- Collected
- Jul 29, 2020 07:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-033PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0176 mg/l
-
- Collected
- Jul 29, 2020 12:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-032PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0359 mg/l
-
- Collected
- Jul 29, 2020 06:13
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-031PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0942 mg/l
-
- Collected
- Jul 29, 2020 06:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-030PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0342 mg/l
-
- Collected
- Jul 29, 2020 06:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-028PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0729 mg/l
-
- Collected
- Jul 29, 2020 05:45
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200803-027PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.019 mg/l
Routine (10).