This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Chemical and radiological sample results
MS0540021 , Chickasaw Hills Subdivision
21 of the 64 analytes this system has been tested for have been detected at least once, across 99 samples on record.
The other 43 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 99 samples on record, detections range from October 13, 2003 to March 25, 2025. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 26 of 26 results | Sep 17, 2008 | Jul 30, 2020 |
| Lead 1030 | Inorganic Chemical | 17 of 26 results | Sep 17, 2008 | Jul 13, 2017 |
| Barium 1010 | Inorganic Chemical | 10 of 10 results | Oct 13, 2003 | Mar 25, 2025 |
| Fluoride 1025 | Inorganic Chemical | 4 of 11 results | Nov 1, 2004 | Mar 25, 2025 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 4 of 7 results | Jun 24, 2010 | Mar 4, 2025 |
| Nickel 1036 | Inorganic Chemical | 3 of 10 results | Oct 13, 2003 | Oct 5, 2022 |
| Sodium 1052 | Inorganic Chemical | 2 of 2 results | Oct 23, 2019 | Jun 3, 2021 |
| Sulfate 1055 | Inorganic Chemical | 2 of 2 results | Oct 13, 2003 | Jun 3, 2021 |
| TTHM 2950 | Organic Chemical | 2 of 7 results | Sep 6, 2007 | Jun 24, 2010 |
| Calcium 1016 | Inorganic Chemical | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Chloride 1017 | Inorganic Chemical | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Conductivity @ 25 C Umhos/CM 1064 | Water Quality | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Color 1905 | Water Quality | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Alkalinity, Total 1927 | Water Quality | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 1 of 3 results | Jul 13, 2020 | Jul 13, 2020 |
| Radium-228 4030 | Radionuclide | 1 of 3 results | Jul 13, 2020 | Jul 13, 2020 |
| Monochloroacetic Acid 2450 | Organic Chemical | 1 of 3 results | Dec 7, 2016 | Dec 7, 2016 |
| Chromium 1020 | Inorganic Chemical | 1 of 10 results | May 1, 2013 | May 1, 2013 |
| Gross Alpha Particle Activity 4109 | Radionuclide | 1 of 4 results | Jun 29, 2012 | Jun 29, 2012 |
| Dichloromethane 2964 | Organic Chemical | 1 of 7 results | Aug 23, 2004 | Aug 23, 2004 |
| Cadmium 1015 | Inorganic Chemical | 1 of 10 results | Oct 13, 2003 | Oct 13, 2003 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 21–30 of 99 samples, newest first — collected July 13, 2017 to July 30, 2020. The summary above covers all 99.
30 results from the 10 samples listed here: 7 detected, 23 not detected. Across the whole record it is 82 of 460. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.4537 mg/l , sample collected Jul 30, 2020 06:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 30, 2020 06:00, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2018 – Dec 31, 2020 |
|
||
| 0.81 pci/l , sample collected Jul 13, 2020 11:30, sampling point TF080 | Combined Radium (-226 & -228) 4010 EPA method 7500-RA | Not recorded |
| Not detected below 0.3 pci/l Minimum Reporting Level , sample collected Jul 13, 2020 11:30, sampling point TF080 | Radium-226 4020 EPA method 7500-RAB | Jan 1, 2012 – Dec 31, 2020 |
| 0.81 pci/l , sample collected Jul 13, 2020 11:30, sampling point TF080 | Radium-228 4030 EPA method 7500-RAD | Jan 1, 2012 – Dec 31, 2020 |
|
||
| Not detected below 1.51 pci/l Minimum Reporting Level , sample collected Jul 13, 2020 11:30, sampling point TF080 | Gross Alpha, Incl. Radon & U 4002 EPA method 7110B | Jan 1, 2012 – Dec 31, 2020 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Apr 22, 2020 13:51, sampling point TF080 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Apr 22, 2020 13:51, sampling point TF080 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Apr 22, 2020 13:51, sampling point TF080 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2020 – Dec 31, 2020 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Dec 4, 2019 15:50, sampling point TF080 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2019 – Dec 31, 2019 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Dec 4, 2019 15:50, sampling point TF080 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2019 – Dec 31, 2019 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Dec 4, 2019 15:50, sampling point TF080 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2019 – Dec 31, 2019 |
|
||
| 7100 ug/l , sample collected Oct 23, 2019 15:21, sampling point TF080 | Sodium 1052 EPA method 200.7 | Not recorded |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Arsenic 1005 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| 0.0338 mg/l , sample collected Oct 23, 2019 13:59, sampling point TF080 | Barium 1010 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Cadmium 1015 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Chromium 1020 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Fluoride 1025 EPA method QC 10-109-12-2-A | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Mercury 1035 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Selenium 1045 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Oct 23, 2019 13:59, sampling point TF080 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
|
||
| Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Jun 11, 2019 02:15, sampling point TF080 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2017 – Dec 31, 2019 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 13, 2018 10:34, sampling point TF080 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Mar 13, 2018 10:34, sampling point TF080 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Mar 13, 2018 10:34, sampling point TF080 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
|
||
| 0.3804 mg/l , sample collected Jul 13, 2017 06:28, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
| 0.0021 mg/l , sample collected Jul 13, 2017 06:28, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
-
- Collected
- Jul 30, 2020 06:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 200731-039PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2020
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.4537 mg/l
-
Lead 1030 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Jul 13, 2020 11:30
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 4674467
- Laboratory
- Eurofins Eaton Analytical South Bend in
-
Combined Radium (-226 & -228) 4010 EPA method 7500-RA
- Result
- 0.81 pci/l
- Monitoring period
- Not recorded
-
Radium-226 4020 EPA method 7500-RAB
- Result
- Not detected below 0.3 pci/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2012 – Dec 31, 2020
-
Radium-228 4030 EPA method 7500-RAD
- Result
- 0.81 pci/l
- Monitoring period
- Jan 1, 2012 – Dec 31, 2020
-
- Collected
- Jul 13, 2020 11:30
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 4674466
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2012 – Dec 31, 2020
-
Gross Alpha, Incl. Radon & U 4002 EPA method 7110B
- Result
- Not detected below 1.51 pci/l Minimum Reporting Level
-
- Collected
- Apr 22, 2020 13:51
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 200423-003NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2020 – Dec 31, 2020
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Dec 4, 2019 15:50
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 191205-017NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2019 – Dec 31, 2019
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Oct 23, 2019 15:21
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 680-175996-3
- Laboratory
- Test America-Savannah
- Monitoring period
- Not recorded
-
Sodium 1052 EPA method 200.7
- Result
- 7100 ug/l
-
- Collected
- Oct 23, 2019 13:59
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 191024-002IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Barium 1010 EPA method 200.8
- Result
- 0.0338 mg/l
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Fluoride 1025 EPA method QC 10-109-12-2-A
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Nickel 1036 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
- Collected
- Jun 11, 2019 02:15
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 190612-003CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 0.015 mg/l Minimum Reporting Level
-
- Collected
- Mar 13, 2018 10:34
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 180314-067NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2018
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Jul 13, 2017 06:28
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 170714-070PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2015 – Dec 31, 2017
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.3804 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0021 mg/l
Routine (10).