Chemical and radiological sample results
MS0540025 , Enid Shores Dev Water Company
21 of the 63 analytes this system has been tested for have been detected at least once, across 103 samples on record.
The other 42 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 103 samples on record, detections range from October 13, 2003 to March 25, 2025. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 25 of 25 results | Jul 27, 2006 | Jul 31, 2020 |
| Nitrate-Nitrite 1038 | Inorganic Chemical | 22 of 23 results | Jun 9, 2004 | Mar 25, 2025 |
| Nitrate 1040 | Inorganic Chemical | 22 of 23 results | Jun 9, 2004 | Mar 25, 2025 |
| Barium 1010 | Inorganic Chemical | 10 of 10 results | Oct 13, 2003 | Mar 25, 2025 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 4 of 8 results | Sep 28, 2006 | Mar 4, 2025 |
| Nickel 1036 | Inorganic Chemical | 3 of 10 results | Jan 27, 2010 | Mar 25, 2025 |
| Lead 1030 | Inorganic Chemical | 3 of 25 results | Jul 27, 2006 | Jun 16, 2011 |
| Chromium 1020 | Inorganic Chemical | 2 of 10 results | May 1, 2013 | Mar 25, 2025 |
| Fluoride 1025 | Inorganic Chemical | 2 of 11 results | Jun 3, 2021 | Mar 25, 2025 |
| Sodium 1052 | Inorganic Chemical | 2 of 2 results | Oct 23, 2019 | Jun 3, 2021 |
| Combined Radium (-226 & -228) 4010 | Radionuclide | 2 of 4 results | Dec 6, 2011 | Mar 28, 2012 |
| Radium-228 4030 | Radionuclide | 2 of 4 results | Dec 6, 2011 | Mar 28, 2012 |
| TTHM 2950 | Organic Chemical | 2 of 7 results | Sep 6, 2007 | Jun 24, 2010 |
| Selenium 1045 | Inorganic Chemical | 2 of 10 results | Oct 13, 2003 | Mar 27, 2006 |
| Calcium 1016 | Inorganic Chemical | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Chloride 1017 | Inorganic Chemical | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Sulfate 1055 | Inorganic Chemical | 1 of 2 results | Jun 3, 2021 | Jun 3, 2021 |
| Conductivity @ 25 C Umhos/CM 1064 | Water Quality | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Alkalinity, Total 1927 | Water Quality | 1 of 1 result | Jun 3, 2021 | Jun 3, 2021 |
| Gross Alpha Particle Activity 4109 | Radionuclide | 1 of 4 results | Sep 17, 2012 | Sep 17, 2012 |
| Dichloromethane 2964 | Organic Chemical | 1 of 7 results | Aug 23, 2004 | Aug 23, 2004 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 71–80 of 103 samples, newest first — collected September 28, 2006 to June 24, 2010. The summary above covers all 103.
54 results from the 10 samples listed here: 11 detected, 43 not detected. Across the whole record it is 110 of 467. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Jun 24, 2010, sampling point MRT000 | Chloroform 2941 EPA method 524.2 | Not recorded |
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Jun 24, 2010, sampling point MRT000 | Bromoform 2942 EPA method 524.2 | Not recorded |
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Jun 24, 2010, sampling point MRT000 | Bromodichloromethane 2943 EPA method 524.2 | Not recorded |
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Jun 24, 2010, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
| 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jun 24, 2010, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2008 – Dec 31, 2010 |
|
||
| Not detected below 15 ug/l Minimum Reporting Level , sample collected Feb 3, 2010, sampling point TF080 | Cyanide 1024 EPA method QC10204001X | Jan 1, 2008 – Dec 31, 2010 |
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Arsenic 1005 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
| 0.017046 mg/l , sample collected Jan 27, 2010, sampling point TF080 | Barium 1010 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Cadmium 1015 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Chromium 1020 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Fluoride 1025 EPA method 380-75WE | Jan 1, 2008 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Mercury 1035 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
| 0.00195 mg/l , sample collected Jan 27, 2010, sampling point TF080 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0025 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Selenium 1045 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jan 27, 2010, sampling point TF080 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2008 – Dec 31, 2010 |
|
||
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | 1,2,4-Trichlorobenzene 2378 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Cis-1,2-Dichloroethylene 2380 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Xylenes, Total 2955 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Dichloromethane 2964 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | O-Dichlorobenzene 2968 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | P-Dichlorobenzene 2969 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Vinyl Chloride 2976 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | 1,1-Dichloroethylene 2977 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Trans-1,2-Dichloroethylene 2979 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | 1,2-Dichloroethane 2980 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | 1,1,1-Trichloroethane 2981 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Carbon Tetrachloride 2982 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | 1,2-Dichloropropane 2983 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Trichloroethylene 2984 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | 1,1,2-Trichloroethane 2985 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Tetrachloroethylene 2987 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Chlorobenzene 2989 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Benzene 2990 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Toluene 2991 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Ethylbenzene 2992 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
| Not detected below 0.0005 mg/l Method Detection Limit , sample collected Oct 15, 2009, sampling point TF080 | Styrene 2996 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2010 |
|
||
| 0.33 mg/l , sample collected Jun 1, 2009, sampling point TF080 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2009 – Dec 31, 2009 |
| 0.33 mg/l , sample collected Jun 1, 2009, sampling point TF080 | Nitrate 1040 EPA method 353.2 | Jan 1, 2009 – Dec 31, 2009 |
| Not detected below 0.05 mg/l Minimum Reporting Level , sample collected Jun 1, 2009, sampling point TF080 | Nitrite 1041 EPA method 353.2 | Jan 1, 2009 – Dec 31, 2009 |
|
||
| 0.28 mg/l , sample collected Oct 27, 2008, sampling point TF080 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2008 – Dec 31, 2008 |
| 0.28 mg/l , sample collected Oct 27, 2008, sampling point TF080 | Nitrate 1040 EPA method 353.2 | Jan 1, 2008 – Dec 31, 2008 |
| Not detected below 0.05 mg/l Minimum Reporting Level , sample collected Oct 27, 2008, sampling point TF080 | Nitrite 1041 EPA method 353.2 | Jan 1, 2008 – Dec 31, 2008 |
|
||
| 0.31 mg/l , sample collected Nov 13, 2007, sampling point TF080 | Nitrate-Nitrite 1038 EPA method 353.2 | Jan 1, 2007 – Dec 31, 2007 |
| 0.31 mg/l , sample collected Nov 13, 2007, sampling point TF080 | Nitrate 1040 EPA method 353.2 | Jan 1, 2007 – Dec 31, 2007 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Nov 13, 2007, sampling point TF080 | Nitrite 1041 EPA method 353.2 | Jan 1, 2007 – Dec 31, 2007 |
|
||
| Not detected below 0.006 mg/l Minimum Reporting Level , sample collected Sep 6, 2007, sampling point MRT000 | Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 | Jan 1, 2005 – Dec 31, 2007 |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 6, 2007, sampling point MRT000 | Chloroform 2941 EPA method 524.2 | Not recorded |
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 6, 2007, sampling point MRT000 | Bromoform 2942 EPA method 524.2 | Not recorded |
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 6, 2007, sampling point MRT000 | Bromodichloromethane 2943 EPA method 524.2 | Not recorded |
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Sep 6, 2007, sampling point MRT000 | Dibromochloromethane 2944 EPA method 524.2 | Not recorded |
| 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 6, 2007, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2007 |
|
||
| 0.0232 mg/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 28, 2006, sampling point MRT000 | Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 | Jan 1, 2005 – Dec 31, 2007 |
-
- Collected
- Jun 24, 2010
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 100625-007TH
- Laboratory
- MSDH Lab
-
Chloroform 2941 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Bromoform 2942 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Bromodichloromethane 2943 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
- Collected
- Feb 3, 2010
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 100204-009CN
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Cyanide 1024 EPA method QC10204001X
- Result
- Not detected below 15 ug/l Minimum Reporting Level
-
- Collected
- Jan 27, 2010
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 100128-057IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Barium 1010 EPA method 200.8
- Result
- 0.017046 mg/l
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Chromium 1020 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Fluoride 1025 EPA method 380-75WE
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Nickel 1036 EPA method 200.8
- Result
- 0.00195 mg/l
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0025 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
- Collected
- Oct 15, 2009
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 091016-005VO
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2010
-
1,2,4-Trichlorobenzene 2378 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Cis-1,2-Dichloroethylene 2380 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Xylenes, Total 2955 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Dichloromethane 2964 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
O-Dichlorobenzene 2968 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
P-Dichlorobenzene 2969 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Vinyl Chloride 2976 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1-Dichloroethylene 2977 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Trans-1,2-Dichloroethylene 2979 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,2-Dichloroethane 2980 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1,1-Trichloroethane 2981 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Carbon Tetrachloride 2982 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,2-Dichloropropane 2983 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Trichloroethylene 2984 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
1,1,2-Trichloroethane 2985 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Tetrachloroethylene 2987 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Chlorobenzene 2989 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Benzene 2990 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Toluene 2991 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Ethylbenzene 2992 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
Styrene 2996 EPA method 524.2
- Result
- Not detected below 0.0005 mg/l Method Detection Limit
-
- Collected
- Jun 1, 2009
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 090602-049NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2009 – Dec 31, 2009
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- 0.33 mg/l
-
Nitrate 1040 EPA method 353.2
- Result
- 0.33 mg/l
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.05 mg/l Minimum Reporting Level
-
- Collected
- Oct 27, 2008
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 081028-017NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2008 – Dec 31, 2008
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- 0.28 mg/l
-
Nitrate 1040 EPA method 353.2
- Result
- 0.28 mg/l
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.05 mg/l Minimum Reporting Level
-
- Collected
- Nov 13, 2007
- Sampling point
- TF080 Treatment Plant T080
- Sample type
- Routine
- Lab sample
- 071114-068NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2007 – Dec 31, 2007
-
Nitrate-Nitrite 1038 EPA method 353.2
- Result
- 0.31 mg/l
-
Nitrate 1040 EPA method 353.2
- Result
- 0.31 mg/l
-
Nitrite 1041 EPA method 353.2
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Sep 6, 2007
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 070907-028HA
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Total Haloacetic Acids (Haa5) 2456 EPA method 552.2
- Result
- Not detected below 0.006 mg/l Minimum Reporting Level
-
- Collected
- Sep 6, 2007
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 070907-018TH
- Laboratory
- MSDH Lab
-
Chloroform 2941 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Bromoform 2942 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Bromodichloromethane 2943 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
Dibromochloromethane 2944 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
- Collected
- Sep 28, 2006
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 060929-003HA
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
Total Haloacetic Acids (Haa5) 2456 EPA method 552.2
- Result
- 0.0232 mg/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.