Lead and copper
MS0550058 , Pearl River Central W/A-Bi Co
Every monitoring period on record is listed here. This page applies no date range. The same list limited to the last two years.
| Analyte | Monitoring period | Samples | 90th percentile | Facility | Data quality |
|---|---|---|---|---|---|
| Copper | Jan 1, 2022 – Dec 31, 2024 | 20 | 0.182 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2022 – Dec 31, 2024 | 20 | 0.0166 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2019 – Dec 31, 2021 | 20 | 0.143 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2019 – Dec 31, 2021 | 20 | 0.007 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2016 – Dec 31, 2018 | 20 | 0.2135 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2016 – Dec 31, 2018 | 20 | 0.0055 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2013 – Dec 31, 2015 | 21 | 0.2042 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2013 – Dec 31, 2015 | 21 | 0.0023 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2010 – Dec 31, 2012 | 10 | 0.1209 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2010 – Dec 31, 2012 | 10 | 0.0024 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2007 – Dec 31, 2009 | 10 | 0.0173 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2007 – Dec 31, 2009 | 10 | 0.0009 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2004 – Dec 31, 2006 | 10 | 0.025 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2004 – Dec 31, 2006 | 10 | 0.0003 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2003 – Dec 31, 2003 | 10 | 0.091 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2003 – Dec 31, 2003 | 10 | 0 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2002 – Dec 31, 2002 | 20 | 0.079 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2002 – Dec 31, 2002 | 20 | 0.001 mg/l | DS000 | Accepted |
| Copper | Jul 1, 2001 – Dec 31, 2001 | 21 | 0.121 mg/l | DS000 | Accepted |
| Lead | Jul 1, 2001 – Dec 31, 2001 | 21 | 0.001 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2001 – Jun 30, 2001 | 18 | 0.129 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2001 – Jun 30, 2001 | 18 | 0.004 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2000 – Dec 31, 2000 | 10 | 0.446 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2000 – Dec 31, 2000 | 10 | 0.115 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1996 – Dec 31, 1996 | 10 | 0.332 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1996 – Dec 31, 1996 | 10 | 0.001 mg/l | DS000 | Accepted |
| Copper | Jul 1, 1995 – Dec 31, 1995 | 20 | 0.724 mg/l | DS000 | Accepted |
| Lead | Jul 1, 1995 – Dec 31, 1995 | 20 | 0 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1995 – Jun 30, 1995 | 21 | 0.44 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1995 – Jun 30, 1995 | 21 | 0.003 mg/l | DS000 | Accepted |
No date of receipt is recorded for any of these summaries.
What the 90th percentile is
The 90th percentile of all samples collected from the distribution system is the standard that the US Environmental Protection Agency has chosen for determining compliance with the Lead and Copper Action Level under the federal Lead and Copper Rule. The 90th percentile is determined by ranking all sample results from lowest to highest and finding a result that is 90% of the number of sample results from the top. For example, if there are 10 sample results, the 90th percentile would be the 9th sample result from the top.
From the help text published with these pages.