Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Chemical and radiological sample results

MS0570004 , City of McComb

25 of the 65 analytes this system has been tested for have been detected at least once, across 395 samples on record.

The other 40 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 395 samples on record, detections range from July 23, 2002 to August 19, 2025. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for City of McComb, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 242 of 242 results Jun 10, 2004 Aug 19, 2025
Lead 1030 Inorganic Chemical 159 of 242 results Jun 10, 2004 Aug 19, 2025
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 20 of 46 results Aug 8, 2005 Nov 1, 2021
Fluoride 1025 Inorganic Chemical 11 of 11 results Jul 23, 2002 Mar 19, 2025
Monochloroacetic Acid 2450 Organic Chemical 11 of 30 results Jun 11, 2012 Jun 11, 2018
Barium 1010 Inorganic Chemical 10 of 10 results Jul 23, 2002 Mar 19, 2025
Arsenic 1005 Inorganic Chemical 9 of 10 results Mar 17, 2004 Mar 19, 2025
TTHM 2950 Organic Chemical 9 of 49 results Aug 4, 2004 Aug 19, 2010
Sodium 1052 Inorganic Chemical 3 of 3 results Oct 15, 2021 Feb 24, 2025
Sulfate 1055 Inorganic Chemical 3 of 3 results Jul 23, 2002 Oct 15, 2021
Chromium 1020 Inorganic Chemical 3 of 10 results Jul 23, 2002 Dec 12, 2016
Cadmium 1015 Inorganic Chemical 2 of 10 results Apr 11, 2005 May 8, 2013
Calcium 1016 Inorganic Chemical 1 of 1 result Oct 15, 2021 Oct 15, 2021
Chloride 1017 Inorganic Chemical 1 of 1 result Oct 15, 2021 Oct 15, 2021
Conductivity @ 25 C Umhos/CM 1064 Water Quality 1 of 1 result Oct 15, 2021 Oct 15, 2021
Alkalinity, Total 1927 Water Quality 1 of 1 result Oct 15, 2021 Oct 15, 2021
Gross Alpha, Incl. Radon & U 4002 Radionuclide 1 of 1 result Sep 17, 2019 Sep 17, 2019
Combined Radium (-226 & -228) 4010 Radionuclide 1 of 3 results Sep 17, 2019 Sep 17, 2019
Radium-226 4020 Radionuclide 1 of 3 results Sep 17, 2019 Sep 17, 2019
Radium-228 4030 Radionuclide 1 of 3 results Sep 17, 2019 Sep 17, 2019
Dichloroacetic Acid 2451 Organic Chemical 1 of 30 results Dec 1, 2016 Dec 1, 2016
Nickel 1036 Inorganic Chemical 1 of 10 results May 8, 2013 May 8, 2013
Monobromoacetic Acid 2453 Organic Chemical 1 of 30 results Sep 3, 2009 Sep 3, 2009
Selenium 1045 Inorganic Chemical 1 of 10 results Apr 11, 2005 Apr 11, 2005
Dichloromethane 2964 Organic Chemical 1 of 7 results Aug 24, 2004 Aug 24, 2004

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 391–395 of 395 samples, newest first — collected February 5, 2002 to March 11, 2004. The summary above covers all 395.

36 results from the 5 samples listed here: 4 detected, 32 not detected. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for City of McComb, every result from 391 to 395 of 395 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Mar 11, 2004
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
040312-003TH
Laboratory
MSDH Lab
Not detected below 1 ug/l Minimum Reporting Level , sample collected Mar 11, 2004, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2004 – Mar 31, 2004
Collected
Feb 26, 2004
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
040227-030VO
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 1,2,4-Trichlorobenzene 2378 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Cis-1,2-Dichloroethylene 2380 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Xylenes, Total 2955 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Dichloromethane 2964 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 O-Dichlorobenzene 2968 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 P-Dichlorobenzene 2969 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Vinyl Chloride 2976 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 1,1-Dichloroethylene 2977 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Trans-1,2-Dichloroethylene 2979 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 1,2-Dichloroethane 2980 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 1,1,1-Trichloroethane 2981 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Carbon Tetrachloride 2982 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 1,2-Dichloropropane 2983 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Trichloroethylene 2984 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 1,1,2-Trichloroethane 2985 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Tetrachloroethylene 2987 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Chlorobenzene 2989 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Benzene 2990 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Toluene 2991 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Ethylbenzene 2992 Jan 1, 2004 – Mar 31, 2004
Not detected below 0.0005 mg/l Method Detection Limit , sample collected Feb 26, 2004, sampling point TF080 Styrene 2996 Jan 1, 2004 – Mar 31, 2004
Collected
Jul 23, 2002
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
020724-013IN
Laboratory
MSDH Lab
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Jul 23, 2002, sampling point TF080 Arsenic 1005 EPA method 200.8 Not recorded
0.005 mg/l , sample collected Jul 23, 2002, sampling point TF080 Barium 1010 EPA method 200.8 Not recorded
Not detected below 0.0001 mg/l Minimum Reporting Level , sample collected Jul 23, 2002, sampling point TF080 Cadmium 1015 EPA method 200.8 Not recorded
0.007 mg/l , sample collected Jul 23, 2002, sampling point TF080 Chromium 1020 EPA method 200.8 Not recorded
0.898 mg/l , sample collected Jul 23, 2002, sampling point TF080 Fluoride 1025 EPA method 300.0 Not recorded
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 23, 2002, sampling point TF080 Mercury 1035 EPA method 200.8 Not recorded
Not detected below 0.005 mg/l Minimum Reporting Level , sample collected Jul 23, 2002, sampling point TF080 Nickel 1036 EPA method 200.8 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Jul 23, 2002, sampling point TF080 Selenium 1045 EPA method 200.8 Not recorded
18.7 mg/l , sample collected Jul 23, 2002, sampling point TF080 Sulfate 1055 EPA method 300.0 Not recorded
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Jul 23, 2002, sampling point TF080 Antimony, Total 1074 EPA method 200.8 Not recorded
Not detected below 0.0003 mg/l Minimum Reporting Level , sample collected Jul 23, 2002, sampling point TF080 Beryllium, Total 1075 EPA method 200.8 Not recorded
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Jul 23, 2002, sampling point TF080 Thallium, Total 1085 EPA method 200.8 Not recorded
Collected
Feb 19, 2002
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
020220-013CN
Laboratory
MSDH Lab
Not detected below 0.01 mg/l Minimum Reporting Level , sample collected Feb 19, 2002, sampling point TF080 Cyanide 1024 EPA method 335.4 Jan 1, 2002 – Dec 31, 2004
Collected
Feb 5, 2002
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
020206-041CN
Laboratory
MSDH Lab
Not detected below 0.01 mg/l Minimum Reporting Level , sample collected Feb 5, 2002, sampling point TF080 Cyanide 1024 EPA method 335.4 Jan 1, 2002 – Dec 31, 2004

Routine (5).