Lead and copper
MS0580006 , City of Pontotoc
Every monitoring period on record is listed here. This page applies no date range. The same list limited to the last two years.
| Analyte | Monitoring period | Samples | 90th percentile | Facility | Data quality |
|---|---|---|---|---|---|
| Copper | Jan 1, 2023 – Dec 31, 2025 | 20 | 0.0745 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2023 – Dec 31, 2025 | 20 | 0.001 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2020 – Dec 31, 2022 | 20 | 0.219 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2020 – Dec 31, 2022 | 20 | 0.0015 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2017 – Dec 31, 2019 | 20 | 0.2031 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2017 – Dec 31, 2019 | 20 | 0.0051 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2014 – Dec 31, 2016 | 20 | 0.2198 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2014 – Dec 31, 2016 | 20 | 0.0027 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2011 – Dec 31, 2013 | 20 | 0.3215 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2011 – Dec 31, 2013 | 20 | 0.0021 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2008 – Dec 31, 2010 | 20 | 0.0867 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2008 – Dec 31, 2010 | 20 | 0.0007 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2005 – Dec 31, 2007 | 20 | 0.2515 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2005 – Dec 31, 2007 | 20 | 0.0017 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2002 – Dec 31, 2004 | 18 | 0.2461 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2002 – Dec 31, 2004 | 18 | 0.0028 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1999 – Dec 31, 2001 | 20 | 0.159 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1999 – Dec 31, 2001 | 20 | 0.001 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1996 – Dec 31, 1998 | 20 | 0.305 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1996 – Dec 31, 1998 | 20 | 0.003 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1995 – Dec 31, 1995 | 20 | 0.38 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1995 – Dec 31, 1995 | 20 | 0.004 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1994 – Dec 31, 1994 | 20 | 0.144 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1994 – Dec 31, 1994 | 20 | 0.003 mg/l | DS000 | Accepted |
| Copper | Jul 1, 1992 – Dec 31, 1992 | 40 | 0.29 mg/l | DS000 | Accepted |
| Lead | Jul 1, 1992 – Dec 31, 1992 | 40 | 0.003 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1992 – Jun 30, 1992 | 40 | 0.21 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1992 – Jun 30, 1992 | 40 | 0.007 mg/l | DS000 | Accepted |
No date of receipt is recorded for any of these summaries.
What the 90th percentile is
The 90th percentile of all samples collected from the distribution system is the standard that the US Environmental Protection Agency has chosen for determining compliance with the Lead and Copper Action Level under the federal Lead and Copper Rule. The 90th percentile is determined by ranking all sample results from lowest to highest and finding a result that is 90% of the number of sample results from the top. For example, if there are 10 sample results, the 90th percentile would be the 9th sample result from the top.