This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
Gross Alpha, Incl. Radon & U results
MS0610038 , V Lakes Utility District
7 samples have been analysed for Gross Alpha, Incl. Radon & U at V Lakes Utility District.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Gross Alpha, Incl. Radon & U result
All 7 samples analysed for this analyte are listed below, newest first. No date range is applied.
7 Gross Alpha, Incl. Radon & U results from the 7 samples listed here: 6 detected, 1 not detected. Those samples also carried 15 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Dec 2, 2015 09:28, sampling point TF104 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Oct 1, 2015 – Dec 31, 2015 |
|
||
| Not detected below 0.317 pci/l Minimum Reporting Level , sample collected Aug 24, 2015 07:27, sampling point TF104 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Jul 1, 2015 – Sep 30, 2015 |
|
||
| 1.6 pci/l , sample collected Jul 20, 2012 15:00, sampling point ST060 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
|
||
| 1.6 pci/l , sample collected Jul 19, 2012 07:46, sampling point ST060 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
|
||
| 1.6 pci/l , sample collected Apr 24, 2012 08:13, sampling point ST060 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
|
||
| 1.6 pci/l , sample collected Feb 13, 2012 10:30, sampling point ST060 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
|
||
| 1.6 pci/l , sample collected Dec 12, 2011 03:00, sampling point ST060 | Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 | Not recorded |
-
- Collected
- Dec 2, 2015 09:28
- Sampling point
- TF104 Treatment Facility TF104
- Sample type
- Routine
- Lab sample
- 201512070040GA
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2015 – Dec 31, 2015
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 0.5 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Aug 24, 2015 07:27
- Sampling point
- TF104 Treatment Facility TF104
- Sample type
- Routine
- Lab sample
- 201509020217GA
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Jul 1, 2015 – Sep 30, 2015
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- Not detected below 0.317 pci/l Minimum Reporting Level
-
- Collected
- Jul 20, 2012 15:00
- Sampling point
- ST060 Ground Tank
- Sample type
- Routine
- Lab sample
- 201210050238
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.6 pci/l
-
- Collected
- Jul 19, 2012 07:46
- Sampling point
- ST060 Ground Tank
- Sample type
- Routine
- Lab sample
- 120720-002
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.6 pci/l
-
- Collected
- Apr 24, 2012 08:13
- Sampling point
- ST060 Ground Tank
- Sample type
- Routine
- Lab sample
- 120425-068
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.6 pci/l
-
- Collected
- Feb 13, 2012 10:30
- Sampling point
- ST060 Ground Tank
- Sample type
- Routine
- Lab sample
- 120214-070
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.6 pci/l
-
- Collected
- Dec 12, 2011 03:00
- Sampling point
- ST060 Ground Tank
- Sample type
- Routine
- Lab sample
- 111213-079
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Not recorded
-
Gross Alpha, Incl. Radon & U 4002 EPA method 00-02
- Result
- 1.6 pci/l
Routine (7).