Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Chemical and radiological sample results

MS0620023 , Steele-Ringgold W/A #2

34 of the 74 analytes this system has been tested for have been detected at least once, across 256 samples on record.

The other 40 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 256 samples on record, detections range from October 22, 2003 to December 29, 2025. These figures cover the whole record.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Steele-Ringgold W/A #2, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 69 of 69 results Aug 14, 2007 Jul 25, 2023
Lead 1030 Inorganic Chemical 52 of 70 results Aug 14, 2007 Jul 25, 2023
Fluoride 1025 Inorganic Chemical 31 of 32 results Oct 22, 2003 Mar 24, 2025
Barium 1010 Inorganic Chemical 27 of 27 results Oct 22, 2003 Mar 24, 2025
Chromium 1020 Inorganic Chemical 18 of 27 results Oct 22, 2003 Mar 24, 2025
Gross Alpha, Incl. Radon & U 4002 Radionuclide 12 of 12 results Mar 13, 2012 Mar 30, 2015
TTHM 2950 Organic Chemical 11 of 11 results Aug 25, 2004 Dec 29, 2025
Sodium 1052 Inorganic Chemical 11 of 11 results Sep 29, 2009 Dec 5, 2023
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 10 of 12 results Jul 7, 2010 Dec 29, 2025
Dichloroacetic Acid 2451 Organic Chemical 7 of 7 results Sep 12, 2007 Dec 29, 2025
Sulfate 1055 Inorganic Chemical 7 of 7 results Oct 22, 2003 Sep 28, 2021
Trichloroacetic Acid 2452 Organic Chemical 6 of 7 results Jul 7, 2010 Dec 29, 2025
Chloroform 2941 Organic Chemical 6 of 6 results Oct 23, 2007 Dec 29, 2025
Bromodichloromethane 2943 Organic Chemical 6 of 6 results Oct 23, 2007 Dec 29, 2025
Nickel 1036 Inorganic Chemical 5 of 27 results May 13, 2013 Mar 24, 2025
Calcium 1016 Inorganic Chemical 5 of 5 results Sep 29, 2009 Sep 28, 2021
Color 1905 Water Quality 5 of 5 results Sep 29, 2009 Sep 28, 2021
Alkalinity, Total 1927 Water Quality 5 of 5 results Sep 29, 2009 Sep 28, 2021
Chloride 1017 Inorganic Chemical 4 of 5 results Dec 7, 2012 Sep 28, 2021
Conductivity @ 25 C Umhos/CM 1064 Water Quality 3 of 3 results Sep 28, 2021 Sep 28, 2021
Potassium 1042 Inorganic Chemical 2 of 2 results Sep 29, 2009 Dec 7, 2012
Residue, Total, Filterable 1057 Water Quality 2 of 2 results Sep 29, 2009 Dec 7, 2012
Alkalinity, Caco3 Stability 1067 Water Quality 2 of 2 results Sep 29, 2009 Dec 7, 2012
Hardness, Total (As Caco3) 1915 Water Quality 2 of 2 results Sep 29, 2009 Dec 7, 2012
Iron, Field Result FEFD Inorganic Chemical 2 of 2 results Sep 29, 2009 Dec 7, 2012
Calculated Sodium NACA Water Quality 2 of 2 results Sep 29, 2009 Dec 7, 2012
PH, Field Result PHFD Water Quality 2 of 2 results Sep 29, 2009 Dec 7, 2012
Xylenes, Total 2955 Organic Chemical 1 of 24 results Nov 28, 2022 Nov 28, 2022
Monochloroacetic Acid 2450 Organic Chemical 1 of 7 results Dec 7, 2016 Dec 7, 2016
Iron 1028 Inorganic Chemical 1 of 2 results Sep 29, 2009 Sep 29, 2009
Manganese 1032 Inorganic Chemical 1 of 1 result Sep 29, 2009 Sep 29, 2009
Carbon Dioxide 1901 Water Quality 1 of 1 result Sep 29, 2009 Sep 29, 2009
PH 1925 Water Quality 1 of 1 result Sep 29, 2009 Sep 29, 2009
Nitrite 1041 Inorganic Chemical 1 of 51 results Aug 2, 2006 Aug 2, 2006

No date range is applied: this list draws on every sample on record. Show the last two years only.

The most recent samples, result by result

The table below lists 161–170 of 256 samples, newest first — collected March 13, 2012 to August 6, 2012. The summary above covers all 256.

26 results from the 10 samples listed here: 4 detected, 22 not detected. Across the whole record it is 321 of 1,328. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for Steele-Ringgold W/A #2, every result from 161 to 170 of 256 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Aug 6, 2012 15:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120807-114RU
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 6, 2012 15:00, sampling point TF101 Combined Uranium 4006 EPA method 200.8 Jul 1, 2012 – Sep 30, 2012
Collected
Aug 6, 2012 14:30
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120807-084RU
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 6, 2012 14:30, sampling point TF102 Combined Uranium 4006 EPA method 200.8 Jul 1, 2012 – Sep 30, 2012
Collected
May 21, 2012 14:05
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120522-144
Laboratory
Radiation Safety Engineering
0.7 pci/l , sample collected May 21, 2012 14:05, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Not detected below 0.53 pci/l Minimum Reporting Level , sample collected May 21, 2012 14:05, sampling point TF101 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.43 pci/l Minimum Reporting Level , sample collected May 21, 2012 14:05, sampling point TF101 Radium-226 4020 EPA method 903.1 Apr 1, 2012 – Jun 30, 2012
Not detected below 0.53 pci/l Minimum Reporting Level , sample collected May 21, 2012 14:05, sampling point TF101 Radium-228 4030 EPA method 904.0 Apr 1, 2012 – Jun 30, 2012
Collected
May 21, 2012 13:35
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120522-118
Laboratory
Radiation Safety Engineering
0.5 pci/l , sample collected May 21, 2012 13:35, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Not detected below 0.57 pci/l Minimum Reporting Level , sample collected May 21, 2012 13:35, sampling point TF102 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.247 pci/l Minimum Reporting Level , sample collected May 21, 2012 13:35, sampling point TF102 Radium-226 4020 EPA method 903.1 Apr 1, 2012 – Jun 30, 2012
Not detected below 0.57 pci/l Minimum Reporting Level , sample collected May 21, 2012 13:35, sampling point TF102 Radium-228 4030 EPA method 904.0 Apr 1, 2012 – Jun 30, 2012
Collected
May 21, 2012 14:08
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120522-144RU
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 21, 2012 14:08, sampling point TF101 Combined Uranium 4006 EPA method 200.8 Apr 1, 2012 – Jun 30, 2012
Collected
May 21, 2012 13:38
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120522-118RU
Laboratory
MSDH Lab
Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 21, 2012 13:38, sampling point TF102 Combined Uranium 4006 EPA method 200.8 Apr 1, 2012 – Jun 30, 2012
Collected
Mar 26, 2012 02:31
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120327-133NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 26, 2012 02:31, sampling point TF102 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Mar 26, 2012 02:31, sampling point TF102 Nitrate 1040 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Mar 26, 2012 02:31, sampling point TF102 Nitrite 1041 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Collected
Mar 26, 2012 02:15
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120327-122NI
Laboratory
MSDH Lab
Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Mar 26, 2012 02:15, sampling point TF101 Nitrate-Nitrite 1038 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Mar 26, 2012 02:15, sampling point TF101 Nitrate 1040 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Mar 26, 2012 02:15, sampling point TF101 Nitrite 1041 EPA method 353.2 Jan 1, 2012 – Dec 31, 2012
Collected
Mar 13, 2012 12:30
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120314-128
Laboratory
Radiation Safety Engineering
0.7 pci/l , sample collected Mar 13, 2012 12:30, sampling point TF101 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Not detected below 0.53 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 12:30, sampling point TF101 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.43 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 12:30, sampling point TF101 Radium-226 4020 EPA method 903.1 Jan 1, 2012 – Mar 31, 2012
Not detected below 0.53 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 12:30, sampling point TF101 Radium-228 4030 EPA method 904.0 Jan 1, 2012 – Mar 31, 2012
Collected
Mar 13, 2012 13:25
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
120314-027
Laboratory
Radiation Safety Engineering
0.5 pci/l , sample collected Mar 13, 2012 13:25, sampling point TF102 Gross Alpha, Incl. Radon & U 4002 EPA method 00-02 Not recorded
Not detected below 0.57 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 13:25, sampling point TF102 Combined Radium (-226 & -228) 4010 Not recorded
Not detected below 0.247 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 13:25, sampling point TF102 Radium-226 4020 EPA method 903.1 Jan 1, 2012 – Mar 31, 2012
Not detected below 0.57 pci/l Minimum Reporting Level , sample collected Mar 13, 2012 13:25, sampling point TF102 Radium-228 4030 EPA method 904.0 Jan 1, 2012 – Mar 31, 2012