Lead and copper
MS0640014 , Smiths Crossing Water Assn
Every monitoring period on record is listed here. This page applies no date range. The same list limited to the last two years.
| Analyte | Monitoring period | Samples | 90th percentile | Facility | Data quality |
|---|---|---|---|---|---|
| Copper | Jan 1, 2023 – Dec 31, 2025 | 20 | 1.24 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2023 – Dec 31, 2025 | 20 | 0.0103 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2020 – Dec 31, 2022 | 20 | 0.6 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2020 – Dec 31, 2022 | 20 | 0.0044 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2017 – Dec 31, 2019 | 20 | 0.4822 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2017 – Dec 31, 2019 | 20 | 0.0016 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2014 – Dec 31, 2016 | 21 | 0.2034 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2014 – Dec 31, 2016 | 21 | 0.0086 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2011 – Dec 31, 2013 | 20 | 0.0183 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2011 – Dec 31, 2013 | 20 | 0.0007 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2008 – Dec 31, 2010 | 20 | 0.0421 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2008 – Dec 31, 2010 | 20 | 0.0014 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2005 – Dec 31, 2007 | 20 | 0.5468 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2005 – Dec 31, 2007 | 20 | 0.0133 mg/l | DS000 | Accepted |
| Copper | Jan 1, 2002 – Dec 31, 2004 | 20 | 0.0453 mg/l | DS000 | Accepted |
| Lead | Jan 1, 2002 – Dec 31, 2004 | 20 | 0.0023 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1999 – Dec 31, 2001 | 20 | 0.015 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1999 – Dec 31, 2001 | 20 | 0.001 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1996 – Dec 31, 1998 | 20 | 0.197 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1996 – Dec 31, 1998 | 20 | 0.003 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1995 – Dec 31, 1995 | 20 | 0.407 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1995 – Dec 31, 1995 | 20 | 0.008 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1994 – Dec 31, 1994 | 20 | 0.218 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1994 – Dec 31, 1994 | 20 | 0.01 mg/l | DS000 | Accepted |
| Copper | Jan 1, 1993 – Jun 30, 1993 | 40 | 0.979 mg/l | DS000 | Accepted |
| Lead | Jan 1, 1993 – Jun 30, 1993 | 40 | 0.013 mg/l | DS000 | Accepted |
| Copper | Jul 1, 1992 – Dec 31, 1992 | 40 | 0.46 mg/l | DS000 | Accepted |
| Lead | Jul 1, 1992 – Dec 31, 1992 | 40 | 0.009 mg/l | DS000 | Accepted |
No date of receipt is recorded for any of these summaries.
What the 90th percentile is
The 90th percentile of all samples collected from the distribution system is the standard that the US Environmental Protection Agency has chosen for determining compliance with the Lead and Copper Action Level under the federal Lead and Copper Rule. The 90th percentile is determined by ranking all sample results from lowest to highest and finding a result that is 90% of the number of sample results from the top. For example, if there are 10 sample results, the 90th percentile would be the 9th sample result from the top.
From the help text published with these pages.