Lead and copper

MS0640019 , Howard Industries

Every monitoring period on record is listed here. This page applies no date range. The same list limited to the last two years.

Lead and copper 90th-percentile sample summaries for Howard Industries, 30 summaries, every one on record. The agency records no date of receipt for any of them.
Analyte Monitoring period Samples 90th percentile Facility Data quality
Copper Jan 1, 2021 – Dec 31, 2023 5 1.82 mg/l DS000 Accepted
Lead Jan 1, 2021 – Dec 31, 2023 5 0.0061 mg/l DS000 Accepted
Copper Jan 1, 2017 – Dec 31, 2019 5 0.372 mg/l DS000 Accepted
Lead Jan 1, 2017 – Dec 31, 2019 5 0.0033 mg/l DS000 Accepted
Copper Jan 1, 2016 – Dec 31, 2016 5 0.2951 mg/l DS000 Accepted
Lead Jan 1, 2016 – Dec 31, 2016 5 0.0023 mg/l DS000 Accepted
Copper Jan 1, 2015 – Dec 31, 2015 6 0.5049 mg/l DS000 Accepted
Lead Jan 1, 2015 – Dec 31, 2015 6 0.0034 mg/l DS000 Accepted
Copper Jan 1, 2014 – Dec 31, 2014 6 0.5277 mg/l DS000 Accepted
Lead Jan 1, 2014 – Dec 31, 2014 6 0.0058 mg/l DS000 Accepted
Copper Jan 1, 2013 – Dec 31, 2013 6 0.7712 mg/l DS000 Accepted
Lead Jan 1, 2013 – Dec 31, 2013 6 0.004 mg/l DS000 Accepted
Copper Jul 1, 2012 – Dec 31, 2012 6 0.8036 mg/l DS000 Accepted
Lead Jul 1, 2012 – Dec 31, 2012 6 0.0031 mg/l DS000 Accepted
Copper Jan 1, 2012 – Jun 30, 2012 5 0.338 mg/l DS000 Accepted
Lead Jan 1, 2012 – Jun 30, 2012 5 0.0044 mg/l DS000 Accepted
Copper Jan 1, 2009 – Dec 31, 2011 6 0.5674 mg/l DS000 Accepted
Lead Jan 1, 2009 – Dec 31, 2011 6 0.0267 mg/l DS000 Accepted
Copper Jan 1, 2006 – Dec 31, 2008 5 0.1332 mg/l DS000 Accepted
Lead Jan 1, 2006 – Dec 31, 2008 5 0.0139 mg/l DS000 Accepted
Copper Jan 1, 2000 – Dec 31, 2002 10 0.261 mg/l DS000 Accepted
Lead Jan 1, 2000 – Dec 31, 2002 10 0.007 mg/l DS000 Accepted
Copper Jan 1, 1996 – Dec 31, 1996 10 0.372 mg/l DS000 Accepted
Lead Jan 1, 1996 – Dec 31, 1996 10 0.002 mg/l DS000 Accepted
Copper Jan 1, 1995 – Dec 31, 1995 10 0.551 mg/l DS000 Accepted
Lead Jan 1, 1995 – Dec 31, 1995 10 0.004 mg/l DS000 Accepted
Copper Jan 1, 1994 – Jun 30, 1994 22 0.41 mg/l DS000 Accepted
Lead Jan 1, 1994 – Jun 30, 1994 22 0.005 mg/l DS000 Accepted
Copper Jul 1, 1993 – Dec 31, 1993 20 0.141 mg/l DS000 Accepted
Lead Jul 1, 1993 – Dec 31, 1993 20 0.003 mg/l DS000 Accepted

No date of receipt is recorded for any of these summaries.

This system’s violations

What the 90th percentile is

The 90th percentile of all samples collected from the distribution system is the standard that the US Environmental Protection Agency has chosen for determining compliance with the Lead and Copper Action Level under the federal Lead and Copper Rule. The 90th percentile is determined by ranking all sample results from lowest to highest and finding a result that is 90% of the number of sample results from the top. For example, if there are 10 sample results, the 90th percentile would be the 9th sample result from the top.

From the help text published with these pages.