Every Chromium result

The table below lists 11–20 of 20 samples, newest first — collected October 27, 2003 to February 8, 2010.

10 Chromium results from the 10 samples listed here: 8 detected, 2 not detected. Those samples also carried 106 results for other analytes, which are on the full results page.

Chromium results for Pineville Water Association #1, from 11 to 20 of 20 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Feb 8, 2010
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
100209-064IN
Laboratory
MSDH Lab
0.0042 mg/l , sample collected Feb 8, 2010, sampling point TF101 Chromium 1020 EPA method 200.8 Jan 1, 2008 – Dec 31, 2010
Collected
Feb 8, 2010
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
100209-063IN
Laboratory
MSDH Lab
0.0021 mg/l , sample collected Feb 8, 2010, sampling point TF102 Chromium 1020 EPA method 200.8 Jan 1, 2008 – Dec 31, 2010
Collected
Apr 10, 2006
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
060411-012IN
Laboratory
MSDH Lab
0.001682 mg/l , sample collected Apr 10, 2006, sampling point TF101 Chromium 1020 EPA method 200.8 Jan 1, 2005 – Dec 31, 2007
Collected
Apr 10, 2006
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
060411-013IN
Laboratory
MSDH Lab
0.002014 mg/l , sample collected Apr 10, 2006, sampling point TF102 Chromium 1020 EPA method 200.8 Jan 1, 2005 – Dec 31, 2007
Collected
Apr 18, 2005
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
050419-109IN
Laboratory
MSDH Lab
0.00121 mg/l , sample collected Apr 18, 2005, sampling point TF102 Chromium 1020 EPA method 200.8 Jan 1, 2005 – Dec 31, 2007
Collected
Apr 18, 2005
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
050419-108IN
Laboratory
MSDH Lab
0.001617 mg/l , sample collected Apr 18, 2005, sampling point TF101 Chromium 1020 EPA method 200.8 Jan 1, 2005 – Dec 31, 2007
Collected
Mar 29, 2004
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
040330-066IN
Laboratory
MSDH Lab
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Mar 29, 2004, sampling point TF101 Chromium 1020 EPA method 200.8 Jan 1, 2002 – Dec 31, 2004
Collected
Mar 29, 2004
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
040330-065IN
Laboratory
MSDH Lab
Not detected below 0.001 mg/l Minimum Reporting Level , sample collected Mar 29, 2004, sampling point TF102 Chromium 1020 EPA method 200.8 Jan 1, 2002 – Dec 31, 2004
Collected
Oct 27, 2003
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
031028-099IN
Laboratory
MSDH Lab
0.003 mg/l , sample collected Oct 27, 2003, sampling point TF102 Chromium 1020 EPA method 200.8 Not recorded
Collected
Oct 27, 2003
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
031028-066IN
Laboratory
MSDH Lab
0.003 mg/l , sample collected Oct 27, 2003, sampling point TF101 Chromium 1020 EPA method 200.8 Not recorded

Routine (10).