Radium-228 results

MS0680013 , West Tallahatchie Utl Assn

7 samples have been analysed for Radium-228 at West Tallahatchie Utl Assn.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Radium-228 result

All 7 samples analysed for this analyte are listed below, newest first. No date range is applied.

7 Radium-228 results from the 7 samples listed here: 1 detected, 6 not detected. Those samples also carried 25 results for other analytes, which are on the full results page.

Radium-228 results for West Tallahatchie Utl Assn, from the 7 samples analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Jul 20, 2012 13:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
201210080003
Laboratory
Radiation Safety Engineering
Not detected below 0.46 pci/l Minimum Reporting Level , sample collected Jul 20, 2012 13:00, sampling point TF101 Radium-228 4030 EPA method 904.0 Jul 1, 2012 – Sep 30, 2012
Collected
Jul 19, 2012 14:20
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120720-034
Laboratory
Radiation Safety Engineering
Not detected below 0.46 pci/l Minimum Reporting Level , sample collected Jul 19, 2012 14:20, sampling point TF101 Radium-228 4030 EPA method 904.0 Jul 1, 2012 – Sep 30, 2012
Collected
Apr 24, 2012 13:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120425-076
Laboratory
Radiation Safety Engineering
Not detected below 0.46 pci/l Minimum Reporting Level , sample collected Apr 24, 2012 13:00, sampling point TF101 Radium-228 4030 EPA method 904.0 Apr 1, 2012 – Jun 30, 2012
Collected
Feb 14, 2012 16:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
120215-108
Laboratory
Radiation Safety Engineering
Not detected below 0.46 pci/l Minimum Reporting Level , sample collected Feb 14, 2012 16:00, sampling point TF101 Radium-228 4030 EPA method 904.0 Jan 1, 2012 – Mar 31, 2012
Collected
Dec 7, 2011 13:00
Sampling point
TF101 Treatment Plant T101
Sample type
Routine
Lab sample
111208-114
Laboratory
Radiation Safety Engineering
Not detected below 0.46 pci/l Minimum Reporting Level , sample collected Dec 7, 2011 13:00, sampling point TF101 Radium-228 4030 EPA method 904.0 Oct 1, 2011 – Dec 31, 2011
Collected
Dec 4, 2011 14:47
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
291490007
Laboratory
Gel Laboratories
Not detected below 0.613 pci/l Minimum Reporting Level , sample collected Dec 4, 2011 14:47, sampling point TF102 Radium-228 4030 EPA method 904.0 Oct 1, 2011 – Dec 31, 2011
Collected
Sep 29, 2011 14:30
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
287348022
Laboratory
Gel Laboratories
0.896 pci/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 29, 2011 14:30, sampling point TF102 Radium-228 4030 EPA method 904.0 Jul 1, 2011 – Sep 30, 2011

Routine (7).