Radium-228 results
MS0690005 , City of Senatobia
44 samples have been analysed for Radium-228 at City of Senatobia.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every Radium-228 result
The table below lists 1–10 of 44 samples, newest first — collected October 11, 2012 to September 30, 2019.
10 Radium-228 results from the 10 samples listed here: 3 detected, 7 not detected. Those samples also carried 26 results for other analytes, which are on the full results page.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 1 pci/l , sample collected Sep 30, 2019 12:50, sampling point TF102 | Radium-228 4030 EPA method 7500-RAD | Jan 1, 2019 – Dec 31, 2024 |
|
||
| 0.97 pci/l , sample collected Sep 24, 2019 13:20, sampling point TF106 | Radium-228 4030 EPA method 7500-RAD | Jan 1, 2019 – Dec 31, 2024 |
|
||
| Not detected below 0.5 pci/l Minimum Reporting Level , sample collected Sep 11, 2018 09:20, sampling point TF102 | Radium-228 4030 EPA method 7500-RAD | Jan 1, 2013 – Dec 31, 2018 |
|
||
| 1 pci/l , sample collected Aug 20, 2018 14:00, sampling point TF106 | Radium-228 4030 EPA method 7500-RAD | Jan 1, 2013 – Dec 31, 2018 |
|
||
| Not detected below 0.47 pci/l Minimum Reporting Level , sample collected Oct 12, 2012 15:13, sampling point TF101 | Radium-228 4030 EPA method 904.0 | Oct 1, 2012 – Dec 31, 2012 |
|
||
| Not detected below 0.41 pci/l Minimum Reporting Level , sample collected Oct 12, 2012 15:25, sampling point TF102 | Radium-228 4030 EPA method 904.0 | Oct 1, 2012 – Dec 31, 2012 |
|
||
| Not detected below 0.44 pci/l Minimum Reporting Level , sample collected Oct 12, 2012 15:00, sampling point TF105 | Radium-228 4030 EPA method 904.0 | Oct 1, 2012 – Dec 31, 2012 |
|
||
| Not detected below 0.57 pci/l Minimum Reporting Level , sample collected Oct 12, 2012 15:40, sampling point TF103 | Radium-228 4030 EPA method 904.0 | Oct 1, 2012 – Dec 31, 2012 |
|
||
| Not detected below 0.4 pci/l Minimum Reporting Level , sample collected Oct 12, 2012 15:50, sampling point TF104 | Radium-228 4030 EPA method 904.0 | Oct 1, 2012 – Dec 31, 2012 |
|
||
| Not detected below 0.47 pci/l Minimum Reporting Level , sample collected Oct 11, 2012 15:40, sampling point TF101 | Radium-228 4030 EPA method 904.0 | Oct 1, 2012 – Dec 31, 2012 |
-
- Collected
- Sep 30, 2019 12:50
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 4441697
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2019 – Dec 31, 2024
-
Radium-228 4030 EPA method 7500-RAD
- Result
- 1 pci/l
-
- Collected
- Sep 24, 2019 13:20
- Sampling point
- TF106 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 4434904
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2019 – Dec 31, 2024
-
Radium-228 4030 EPA method 7500-RAD
- Result
- 0.97 pci/l
-
- Collected
- Sep 11, 2018 09:20
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 4052782
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2013 – Dec 31, 2018
-
Radium-228 4030 EPA method 7500-RAD
- Result
- Not detected below 0.5 pci/l Minimum Reporting Level
-
- Collected
- Aug 20, 2018 14:00
- Sampling point
- TF106 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 4028967
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Jan 1, 2013 – Dec 31, 2018
-
Radium-228 4030 EPA method 7500-RAD
- Result
- 1 pci/l
-
- Collected
- Oct 12, 2012 15:13
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 201301130152
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2012 – Dec 31, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.47 pci/l Minimum Reporting Level
-
- Collected
- Oct 12, 2012 15:25
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 201301130151
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2012 – Dec 31, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.41 pci/l Minimum Reporting Level
-
- Collected
- Oct 12, 2012 15:00
- Sampling point
- TF105 Treatment Plant T105
- Sample type
- Routine
- Lab sample
- 201301130111
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2012 – Dec 31, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.44 pci/l Minimum Reporting Level
-
- Collected
- Oct 12, 2012 15:40
- Sampling point
- TF103 Treatment Plant T103
- Sample type
- Routine
- Lab sample
- 201301130109
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2012 – Dec 31, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.57 pci/l Minimum Reporting Level
-
- Collected
- Oct 12, 2012 15:50
- Sampling point
- TF104 Treatment Plant T104
- Sample type
- Routine
- Lab sample
- 201301130106
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2012 – Dec 31, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.4 pci/l Minimum Reporting Level
-
- Collected
- Oct 11, 2012 15:40
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 121012-042
- Laboratory
- Radiation Safety Engineering
- Monitoring period
- Oct 1, 2012 – Dec 31, 2012
-
Radium-228 4030 EPA method 904.0
- Result
- Not detected below 0.47 pci/l Minimum Reporting Level
Routine (10).