TTHM results
MS0700009 , Spout Springs W/A
18 samples have been analysed for TTHM at Spout Springs W/A.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every TTHM result
The table below lists 11–18 of 18 samples, newest first — collected August 25, 2004 to May 20, 2024.
8 TTHM results from the 8 samples listed here: 5 detected, 3 not detected. Those samples also carried 30 results for other analytes, which are on the full results page.
Units in this table
TTHM is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.
We withheld the location of 1 sampling point below. The location on record identifies a private home, and we do not publish those. That is our decision, not the agency’s. The sampling point, its type and every result taken there are published unchanged.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 1.12 ug/l , sample collected May 20, 2024 08:45, sampling point SM2 | TTHM 2950 EPA method 524.2 | Apr 1, 2024 – Jun 30, 2024 |
|
||
| 1.83 ug/l , sample collected Aug 29, 2023 14:45, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Not recorded |
|
||
| 3.1 ug/l , sample collected Oct 26, 2020 12:37, sampling point MRT000 | TTHM 2950 | Not recorded |
|
||
| Not detected below 4 ug/l Minimum Reporting Level , sample collected Aug 22, 2016 03:25, sampling point MRT000 | TTHM 2950 | Jan 1, 2014 – Dec 31, 2016 |
|
||
| Not detected below 4 ug/l Minimum Reporting Level , sample collected Sep 10, 2013 03:18, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2011 – Dec 31, 2013 |
|
||
| 1.06 ug/l , sample collected Jul 13, 2010, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2008 – Dec 31, 2010 |
|
||
| 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Sep 11, 2007, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2005 – Dec 31, 2007 |
|
||
| Not detected below 1 ug/l Minimum Reporting Level , sample collected Aug 25, 2004, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2004 – Dec 31, 2004 |
-
- Collected
- May 20, 2024 08:45
- Sampling point
- SM2 Location withheld
- Sample type
- Routine
- Lab sample
- 810-105378-1
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Apr 1, 2024 – Jun 30, 2024
-
TTHM 2950 EPA method 524.2
- Result
- 1.12 ug/l
-
- Collected
- Aug 29, 2023 14:45
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- TH-230830-001
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- 1.83 ug/l
-
- Collected
- Oct 26, 2020 12:37
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 201027-005TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
TTHM 2950
- Result
- 3.1 ug/l
-
- Collected
- Aug 22, 2016 03:25
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 160823-025TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2014 – Dec 31, 2016
-
TTHM 2950
- Result
- Not detected below 4 ug/l Minimum Reporting Level
-
- Collected
- Sep 10, 2013 03:18
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 130911-012TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2011 – Dec 31, 2013
-
TTHM 2950 EPA method 524.2
- Result
- Not detected below 4 ug/l Minimum Reporting Level
-
- Collected
- Jul 13, 2010
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 100714-004TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2008 – Dec 31, 2010
-
TTHM 2950 EPA method 524.2
- Result
- 1.06 ug/l
-
- Collected
- Sep 11, 2007
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 070912-017TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2005 – Dec 31, 2007
-
TTHM 2950 EPA method 524.2
- Result
- 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Aug 25, 2004
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 040826-014TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2004 – Dec 31, 2004
-
TTHM 2950 EPA method 524.2
- Result
- Not detected below 1 ug/l Minimum Reporting Level
Routine (8).