26 of the 57 analytes this system has been tested for have been detected at least once, across 203 samples on record.

The other 31 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 203 samples on record, detections range from October 29, 2003 to March 31, 2025. These figures cover the whole record; the list of samples further down is narrowed.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Spout Springs W/A, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 34 of 34 results Jul 10, 2007 Jul 31, 2023
Barium 1010 Inorganic Chemical 24 of 24 results Oct 29, 2003 Mar 31, 2025
Nickel 1036 Inorganic Chemical 23 of 24 results Oct 29, 2003 Mar 31, 2025
Chromium 1020 Inorganic Chemical 18 of 24 results Oct 29, 2003 Mar 31, 2025
Fluoride 1025 Inorganic Chemical 17 of 24 results Oct 29, 2003 Mar 31, 2025
TTHM 2950 Organic Chemical 10 of 18 results Sep 11, 2007 Feb 10, 2025
Lead 1030 Inorganic Chemical 10 of 34 results Jul 10, 2007 Sep 2, 2020
Gross Alpha, Incl. Radon & U 4002 Radionuclide 10 of 10 results Dec 7, 2011 Jul 10, 2012
Dibromochloromethane 2944 Organic Chemical 8 of 15 results Jul 13, 2010 Feb 10, 2025
Bromodichloromethane 2943 Organic Chemical 7 of 15 results Oct 26, 2020 Feb 10, 2025
Selenium 1045 Inorganic Chemical 5 of 24 results May 2, 2005 Oct 30, 2023
Combined Radium (-226 & -228) 4010 Radionuclide 5 of 10 results Dec 7, 2011 Jul 10, 2012
Radium-228 4030 Radionuclide 5 of 10 results Dec 7, 2011 Jul 10, 2012
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 4 of 18 results Jul 13, 2010 Jul 8, 2024
Sodium 1052 Inorganic Chemical 4 of 4 results Sep 23, 2019 Mar 28, 2023
Sulfate 1055 Inorganic Chemical 4 of 4 results Oct 29, 2003 Apr 7, 2004
Chloroform 2941 Organic Chemical 3 of 15 results May 20, 2024 Feb 10, 2025
Cadmium 1015 Inorganic Chemical 3 of 24 results Apr 7, 2004 Oct 30, 2023
Arsenic 1005 Inorganic Chemical 1 of 24 results Oct 30, 2023 Oct 30, 2023
Antimony, Total 1074 Inorganic Chemical 1 of 24 results Oct 30, 2023 Oct 30, 2023
Beryllium, Total 1075 Inorganic Chemical 1 of 24 results Oct 30, 2023 Oct 30, 2023
Thallium, Total 1085 Inorganic Chemical 1 of 24 results Oct 30, 2023 Oct 30, 2023
Xylenes, Total 2955 Organic Chemical 1 of 22 results Oct 3, 2022 Oct 3, 2022
Monobromoacetic Acid 2453 Organic Chemical 1 of 14 results Oct 26, 2020 Oct 26, 2020
Cyanide 1024 Inorganic Chemical 1 of 26 results Sep 30, 2013 Sep 30, 2013
Nitrite 1041 Inorganic Chemical 1 of 46 results Apr 2, 2012 Apr 2, 2012

Showing samples collected between September 25, 2024 and September 25, 2026. That is this page’s default, not a limit on what the agency records.

Show every sample on record

Choose a date range

The most recent samples, result by result

The table below lists 11–11 of 11 samples, newest first — collected October 7, 2024 to October 7, 2024. The summary above covers all 11.

1 result from the 1 sample listed here: 0 detected, 1 not detected. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

Chemical and radiological sample results for Spout Springs W/A, every result from 11 to 11 of 11 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Oct 7, 2024 10:24
Sampling point
TF102 Treatment Plant T102
Sample type
Routine
Lab sample
CN-241008-010
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Oct 7, 2024 10:24, sampling point TF102 Cyanide 1024 EPA method QC10204001X Jan 1, 2024 – Dec 31, 2024

Routine (1).