Chemical and radiological sample results
MS0700014 , Three Forks Water Association
22 of the 57 analytes this system has been tested for have been detected at least once, across 207 samples on record.
The other 35 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.
Across all 207 samples on record, detections range from October 29, 2003 to July 20, 2026. These figures cover the whole record.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
What has been detected, ever
Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.
| Analyte | Kind | Detected in | First detected | Last detected |
|---|---|---|---|---|
| Copper, Free 1022 | Inorganic Chemical | 60 of 60 results | Aug 16, 2007 | Aug 10, 2023 |
| Lead 1030 | Inorganic Chemical | 41 of 60 results | Aug 16, 2007 | Aug 10, 2023 |
| Barium 1010 | Inorganic Chemical | 20 of 20 results | Oct 29, 2003 | Mar 31, 2025 |
| Fluoride 1025 | Inorganic Chemical | 20 of 20 results | Oct 29, 2003 | Mar 31, 2025 |
| Nickel 1036 | Inorganic Chemical | 15 of 20 results | Mar 31, 2004 | Mar 31, 2025 |
| Gross Alpha, Incl. Radon & U 4002 | Radionuclide | 10 of 10 results | Dec 21, 2011 | Jul 11, 2012 |
| Chromium 1020 | Inorganic Chemical | 9 of 20 results | Mar 31, 2004 | Mar 31, 2025 |
| Sodium 1052 | Inorganic Chemical | 6 of 6 results | Oct 7, 2019 | Jul 20, 2026 |
| TTHM 2950 | Organic Chemical | 5 of 17 results | Sep 11, 2007 | Nov 25, 2024 |
| Total Haloacetic Acids (Haa5) 2456 | Organic Chemical | 4 of 18 results | Jul 15, 2010 | Nov 25, 2024 |
| Sulfate 1055 | Inorganic Chemical | 4 of 4 results | Oct 29, 2003 | Mar 31, 2004 |
| Dichloroacetic Acid 2451 | Organic Chemical | 3 of 13 results | Oct 29, 2020 | Nov 25, 2024 |
| Chloroform 2941 | Organic Chemical | 3 of 13 results | Sep 13, 2016 | Nov 25, 2024 |
| Nitrite 1041 | Inorganic Chemical | 3 of 43 results | May 20, 2020 | Apr 6, 2022 |
| Nitrate-Nitrite 1038 | Inorganic Chemical | 3 of 43 results | Apr 4, 2011 | May 20, 2020 |
| Trichloroacetic Acid 2452 | Organic Chemical | 2 of 13 results | Nov 25, 2024 | Nov 25, 2024 |
| Bromodichloromethane 2943 | Organic Chemical | 2 of 13 results | Nov 25, 2024 | Nov 25, 2024 |
| Dibromochloromethane 2944 | Organic Chemical | 2 of 13 results | Nov 25, 2024 | Nov 25, 2024 |
| Nitrate 1040 | Inorganic Chemical | 2 of 43 results | Apr 4, 2011 | Apr 4, 2011 |
| Selenium 1045 | Inorganic Chemical | 2 of 20 results | Mar 1, 2010 | Mar 1, 2010 |
| Cadmium 1015 | Inorganic Chemical | 2 of 20 results | Mar 31, 2004 | Mar 31, 2004 |
| Monobromoacetic Acid 2453 | Organic Chemical | 1 of 13 results | Oct 29, 2020 | Oct 29, 2020 |
No date range is applied: this list draws on every sample on record. Show the last two years only.
The most recent samples, result by result
The table below lists 71–80 of 207 samples, newest first — collected August 16, 2017 to May 15, 2019. The summary above covers all 207.
31 results from the 10 samples listed here: 16 detected, 15 not detected. Across the whole record it is 219 of 1,035. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 15, 2019 01:40, sampling point TF102 | Arsenic 1005 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| 0.1743 mg/l , sample collected May 15, 2019 01:40, sampling point TF102 | Barium 1010 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 15, 2019 01:40, sampling point TF102 | Cadmium 1015 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| 0.0011 mg/l , sample collected May 15, 2019 01:40, sampling point TF102 | Chromium 1020 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| 0.109 mg/l , sample collected May 15, 2019 01:40, sampling point TF102 | Fluoride 1025 EPA method 300.0 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 15, 2019 01:40, sampling point TF102 | Mercury 1035 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| 0.0016 mg/l , sample collected May 15, 2019 01:40, sampling point TF102 | Nickel 1036 EPA method 200.8 | Not recorded |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 15, 2019 01:40, sampling point TF102 | Selenium 1045 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 15, 2019 01:40, sampling point TF102 | Antimony, Total 1074 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 15, 2019 01:40, sampling point TF102 | Beryllium, Total 1075 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected May 15, 2019 01:40, sampling point TF102 | Thallium, Total 1085 EPA method 200.8 | Jan 1, 2017 – Dec 31, 2019 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Apr 4, 2018 12:45, sampling point TF101 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Apr 4, 2018 12:45, sampling point TF101 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Apr 4, 2018 12:45, sampling point TF101 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
|
||
| Not detected below 0.1 mg/l Minimum Reporting Level , sample collected Apr 4, 2018 12:50, sampling point TF102 | Nitrate-Nitrite 1038 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
| Not detected below 0.08 mg/l Minimum Reporting Level , sample collected Apr 4, 2018 12:50, sampling point TF102 | Nitrate 1040 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
| Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Apr 4, 2018 12:50, sampling point TF102 | Nitrite 1041 EPA method QC10107041C | Jan 1, 2018 – Dec 31, 2018 |
|
||
| 0.0341 mg/l , sample collected Aug 16, 2017 06:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
| 0.001 mg/l , sample collected Aug 16, 2017 06:30, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
|
||
| 0.0296 mg/l , sample collected Aug 16, 2017 06:00, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
| 0.0011 mg/l , sample collected Aug 16, 2017 06:00, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
|
||
| 0.0051 mg/l , sample collected Aug 16, 2017 06:15, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 16, 2017 06:15, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
|
||
| 0.0105 mg/l , sample collected Aug 16, 2017 06:20, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
| 0.0014 mg/l , sample collected Aug 16, 2017 06:20, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
|
||
| 0.1139 mg/l , sample collected Aug 16, 2017 06:15, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
| 0.0026 mg/l , sample collected Aug 16, 2017 06:15, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
|
||
| 0.051 mg/l , sample collected Aug 16, 2017 05:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
| 0.0017 mg/l , sample collected Aug 16, 2017 05:30, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
|
||
| 0.0058 mg/l , sample collected Aug 16, 2017 05:30, sampling point DS000 | Copper, Free 1022 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
| Not detected below 0.0005 mg/l Minimum Reporting Level , sample collected Aug 16, 2017 05:30, sampling point DS000 | Lead 1030 EPA method 200.8 | Jan 1, 2015 – Dec 31, 2017 |
-
- Collected
- May 15, 2019 01:40
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 190516-014IN
- Laboratory
- MSDH Lab
-
Arsenic 1005 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Barium 1010 EPA method 200.8
- Result
- 0.1743 mg/l
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Cadmium 1015 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Chromium 1020 EPA method 200.8
- Result
- 0.0011 mg/l
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Fluoride 1025 EPA method 300.0
- Result
- 0.109 mg/l
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Mercury 1035 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Nickel 1036 EPA method 200.8
- Result
- 0.0016 mg/l
- Monitoring period
- Not recorded
-
Selenium 1045 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Antimony, Total 1074 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Beryllium, Total 1075 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
Thallium, Total 1085 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
- Monitoring period
- Jan 1, 2017 – Dec 31, 2019
-
- Collected
- Apr 4, 2018 12:45
- Sampling point
- TF101 Treatment Plant T101
- Sample type
- Routine
- Lab sample
- 180405-015NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2018
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Apr 4, 2018 12:50
- Sampling point
- TF102 Treatment Plant T102
- Sample type
- Routine
- Lab sample
- 180405-006NI
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2018 – Dec 31, 2018
-
Nitrate-Nitrite 1038 EPA method QC10107041C
- Result
- Not detected below 0.1 mg/l Minimum Reporting Level
-
Nitrate 1040 EPA method QC10107041C
- Result
- Not detected below 0.08 mg/l Minimum Reporting Level
-
Nitrite 1041 EPA method QC10107041C
- Result
- Not detected below 0.02 mg/l Minimum Reporting Level
-
- Collected
- Aug 16, 2017 06:30
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 170817-092PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2015 – Dec 31, 2017
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0341 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.001 mg/l
-
- Collected
- Aug 16, 2017 06:00
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 170817-091PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2015 – Dec 31, 2017
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0296 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0011 mg/l
-
- Collected
- Aug 16, 2017 06:15
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 170817-090PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2015 – Dec 31, 2017
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0051 mg/l
-
Lead 1030 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
-
- Collected
- Aug 16, 2017 06:20
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 170817-089PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2015 – Dec 31, 2017
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0105 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0014 mg/l
-
- Collected
- Aug 16, 2017 06:15
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 170817-088PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2015 – Dec 31, 2017
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.1139 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0026 mg/l
-
- Collected
- Aug 16, 2017 05:30
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 170817-087PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2015 – Dec 31, 2017
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.051 mg/l
-
Lead 1030 EPA method 200.8
- Result
- 0.0017 mg/l
-
- Collected
- Aug 16, 2017 05:30
- Sampling point
- DS000 Distribution
- Sample type
- Routine
- Lab sample
- 170817-086PB
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2015 – Dec 31, 2017
-
Copper, Free 1022 EPA method 200.8
- Result
- 0.0058 mg/l
-
Lead 1030 EPA method 200.8
- Result
- Not detected below 0.0005 mg/l Minimum Reporting Level
Routine (10).