Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

TTHM results

MS0760003 , Glen Allan Utility District

41 samples have been analysed for TTHM at Glen Allan Utility District.

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every TTHM result

The table below lists 31–40 of 41 samples, newest first — collected November 28, 2005 to November 5, 2008.

10 TTHM results from the 10 samples listed here: 10 detected, 0 not detected. Those samples also carried 32 results for other analytes, which are on the full results page.

Units in this table

TTHM is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.

TTHM results for Glen Allan Utility District, from 31 to 40 of 41 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Nov 5, 2008
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
081107-001TH
Laboratory
MSDH Lab
57.84 ug/l , sample collected Nov 5, 2008, sampling point MRT000 TTHM 2950 EPA method 524.2 Oct 1, 2008 – Dec 31, 2008
Collected
Sep 10, 2008
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
080911-005TH
Laboratory
MSDH Lab
47.19 ug/l , sample collected Sep 10, 2008, sampling point MRT000 TTHM 2950 EPA method 524.2 Jul 1, 2008 – Sep 30, 2008
Collected
Jun 3, 2008
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
080604-019TH
Laboratory
MSDH Lab
33.94 ug/l , sample collected Jun 3, 2008, sampling point MRT000 TTHM 2950 EPA method 524.2 Apr 1, 2008 – Jun 30, 2008
Collected
Feb 27, 2008
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
080228-001TH
Laboratory
MSDH Lab
42.02 ug/l , sample collected Feb 27, 2008, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2008 – Mar 31, 2008
Collected
Oct 17, 2007
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
071018-001TH
Laboratory
MSDH Lab
49.34 ug/l , sample collected Oct 17, 2007, sampling point MRT000 TTHM 2950 EPA method 524.2 Oct 1, 2007 – Dec 31, 2007
Collected
Jul 25, 2007
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
070726-004TH
Laboratory
MSDH Lab
39.22 ug/l , sample collected Jul 25, 2007, sampling point MRT000 TTHM 2950 EPA method 524.2 Jul 1, 2007 – Sep 30, 2007
Collected
May 14, 2007
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
070515-002TH
Laboratory
MSDH Lab
26.16 ug/l , sample collected May 14, 2007, sampling point MRT000 TTHM 2950 EPA method 524.2 Apr 1, 2007 – Jun 30, 2007
Collected
Mar 12, 2007
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
070313-012TH
Laboratory
MSDH Lab
32.32 ug/l , sample collected Mar 12, 2007, sampling point MRT000 TTHM 2950 EPA method 524.2 Jan 1, 2007 – Mar 31, 2007
Collected
Oct 3, 2006
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
061004-002TH
Laboratory
MSDH Lab
45 ug/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Oct 3, 2006, sampling point MRT000 TTHM 2950 EPA method 524.2 Oct 1, 2006 – Dec 31, 2006
Collected
Nov 28, 2005
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
051129-001TH
Laboratory
MSDH Lab
111 ug/l , sample collected Nov 28, 2005, sampling point MRT000 TTHM 2950 EPA method 524.2 Oct 1, 2005 – Dec 31, 2005

Routine (10).