Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Total Haloacetic Acids (Haa5) results

MS0760014 , City of Greenville (Airbase)

21 samples have been analysed for Total Haloacetic Acids (Haa5) at City of Greenville (Airbase).

This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

No date range is applied: this list draws on every sample on record. Show the last two years only.

Every Total Haloacetic Acids (Haa5) result

The table below lists 1–10 of 21 samples, newest first — collected February 3, 2009 to February 25, 2025.

10 Total Haloacetic Acids (Haa5) results from the 10 samples listed here: 10 detected, 0 not detected. Those samples also carried 40 results for other analytes, which are on the full results page.

Units in this table

Total Haloacetic Acids (Haa5) is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.

Total Haloacetic Acids (Haa5) results for City of Greenville (Airbase), from 1 to 10 of 21 samples shown analysed for it, newest first. This view leaves out other analytes on the same samples. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Feb 25, 2025 13:30
Sampling point
SMD Airport Maintenance Shop
Sample type
Routine
Lab sample
HA-250226-003
Laboratory
MSDH Lab
19 ug/l , sample collected Feb 25, 2025 13:30, sampling point SMD Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2023 – Dec 31, 2025
Collected
Dec 6, 2022 13:50
Sampling point
SMD Airport Maintenance Shop
Sample type
Routine
Lab sample
HA-221207-012
Laboratory
MSDH Lab
25.1 ug/l , sample collected Dec 6, 2022 13:50, sampling point SMD Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2020 – Dec 31, 2022
Collected
Aug 29, 2016 01:32
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
160830-003HA
Laboratory
MSDH Lab
0.026 mg/l , sample collected Aug 29, 2016 01:32, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2014 – Dec 31, 2016
Collected
Jun 20, 2013 04:30
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
130621-002HA
Laboratory
MSDH Lab
0.015 mg/l , sample collected Jun 20, 2013 04:30, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2013 – Dec 31, 2013
Collected
Jul 17, 2012 01:35
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
120718-004HA
Laboratory
MSDH Lab
0.012 mg/l , sample collected Jul 17, 2012 01:35, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2012 – Dec 31, 2012
Collected
Aug 11, 2011
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
110812-004HA
Laboratory
MSDH Lab
0.053 mg/l , sample collected Aug 11, 2011, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2011 – Dec 31, 2011
Collected
Aug 24, 2010
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
100825-002HA
Laboratory
MSDH Lab
0 mg/l This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. , sample collected Aug 24, 2010, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2010 – Dec 31, 2010
Collected
Jul 27, 2009
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
090728-010HA
Laboratory
MSDH Lab
0 mg/l This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. , sample collected Jul 27, 2009, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jul 1, 2009 – Sep 30, 2009
Collected
Jun 3, 2009
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
090604-011HA
Laboratory
MSDH Lab
0 mg/l This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. , sample collected Jun 3, 2009, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Apr 1, 2009 – Jun 30, 2009
Collected
Feb 3, 2009
Sampling point
MRT000 Max. Res. Time
Sample type
Routine
Lab sample
090204-004HA
Laboratory
MSDH Lab
0.01 mg/l , sample collected Feb 3, 2009, sampling point MRT000 Total Haloacetic Acids (Haa5) 2456 Jan 1, 2009 – Mar 31, 2009

Routine (10).