This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
TTHM results
MS0780009 , Sapa Water System
36 samples have been analysed for TTHM at Sapa Water System.
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
No date range is applied: this list draws on every sample on record. Show the last two years only.
Every TTHM result
The table below lists 31–36 of 36 samples, newest first — collected November 15, 2004 to February 14, 2012.
6 TTHM results from the 6 samples listed here: 6 detected, 0 not detected. Those samples also carried 20 results for other analytes, which are on the full results page.
Units in this table
TTHM is recorded on this page in ug/l and mg/l. 1 mg/l = 1,000 ug/l.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 4.11 ug/l , sample collected Feb 14, 2012 01:00, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2012 – Mar 31, 2012 |
|
||
| 78 ug/l , sample collected Jul 5, 2011 12:20, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jul 1, 2011 – Sep 30, 2011 |
|
||
| 4.21 ug/l , sample collected Sep 1, 2009, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2009 – Dec 31, 2009 |
|
||
| 1.93 ug/l , sample collected Jul 7, 2008, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2008 – Dec 31, 2008 |
|
||
| 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jun 18, 2007, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Jan 1, 2007 – Dec 31, 2007 |
|
||
| 7.43 ug/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Nov 15, 2004, sampling point MRT000 | TTHM 2950 EPA method 524.2 | Not recorded |
-
- Collected
- Feb 14, 2012 01:00
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 120215-012TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2012 – Mar 31, 2012
-
TTHM 2950 EPA method 524.2
- Result
- 4.11 ug/l
-
- Collected
- Jul 5, 2011 12:20
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 110706-013TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2011 – Sep 30, 2011
-
TTHM 2950 EPA method 524.2
- Result
- 78 ug/l
-
- Collected
- Sep 1, 2009
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 090902-007TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2009 – Dec 31, 2009
-
TTHM 2950 EPA method 524.2
- Result
- 4.21 ug/l
-
- Collected
- Jul 7, 2008
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 080708-015TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2008 – Dec 31, 2008
-
TTHM 2950 EPA method 524.2
- Result
- 1.93 ug/l
-
- Collected
- Jun 18, 2007
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 070619-002TH
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2007 – Dec 31, 2007
-
TTHM 2950 EPA method 524.2
- Result
- 0 This result is recorded as a detection, and the figure the agency wrote — "0.00" — is zero to the precision it was written to. Read the zero as "smaller than the written figure resolves", not as "none present". SDWIS holds a separate numeric concentration that Drinking Water Watch does not publish, so this endpoint does not carry it either; no more precise magnitude is available here. The agency recorded a value but no unit of measure for it. The unit is NOT inferable from the analyte: many analytes are reported in more than one unit — TTHM and HAA5 in both MG/L and UG/L — so there is no per-analyte default to fall back on. The number is published as it stands and must not be compared to a limit. The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
-
- Collected
- Nov 15, 2004
- Sampling point
- MRT000 Max. Res. Time
- Sample type
- Routine
- Lab sample
- 041116-001TH
- Laboratory
- MSDH Lab
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- 7.43 ug/l The agency recorded which kind of limit this result was below, but stored 0.000000000 as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType.
Routine (6).