This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.
TTHM results
MS0820003 , Casey Jones Water Assn.
12 samples have been analysed for TTHM at Casey Jones Water Assn..
This is one analyte out of the system’s whole record. For what has ever been detected here, and when, see all chemical and radiological results; for everything the system is tested for, see the analyte list.
What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.
Showing samples collected between September 25, 2024 and September 25, 2026. That is this page’s default, not a limit on what the agency records.
Choose a date range
Every TTHM result
The table below lists 1–10 of 12 samples, newest first — collected January 29, 2025 to February 11, 2026.
10 TTHM results from the 10 samples listed here: 10 detected, 0 not detected. Those samples also carried 20 results for other analytes, which are on the full results page.
We withheld the location of 2 sampling points below. The location on record identifies a private home, and we do not publish those. That is our decision, not the agency’s. The sampling point, its type and every result taken there are published unchanged.
| Result | Analyte | Monitoring period |
|---|---|---|
|
||
| 39.1 ug/l , sample collected Feb 11, 2026 08:45, sampling point SMT | TTHM 2950 EPA method 524.2 | Not recorded |
|
||
| 23 ug/l , sample collected Feb 11, 2026 08:30, sampling point SMH | TTHM 2950 EPA method 524.2 | Not recorded |
|
||
| 48.4 ug/l , sample collected Oct 16, 2025 09:15, sampling point SMT | TTHM 2950 EPA method 524.2 | Oct 1, 2025 – Dec 31, 2025 |
|
||
| 33.1 ug/l , sample collected Oct 16, 2025 09:45, sampling point SMH | TTHM 2950 EPA method 524.2 | Oct 1, 2025 – Dec 31, 2025 |
|
||
| 55 ug/l , sample collected Aug 6, 2025 09:55, sampling point SMT | TTHM 2950 EPA method 524.2 | Jul 1, 2025 – Sep 30, 2025 |
|
||
| 31.1 ug/l , sample collected Aug 6, 2025 09:10, sampling point SMH | TTHM 2950 EPA method 524.2 | Jul 1, 2025 – Sep 30, 2025 |
|
||
| 58.7 ug/l , sample collected Apr 22, 2025 07:50, sampling point SMT | TTHM 2950 EPA method 524.2 | Apr 1, 2025 – Jun 30, 2025 |
|
||
| 25.9 ug/l , sample collected Apr 22, 2025 08:20, sampling point SMH | TTHM 2950 EPA method 524.2 | Apr 1, 2025 – Jun 30, 2025 |
|
||
| 64.6 ug/l , sample collected Jan 29, 2025 07:35, sampling point SMT | TTHM 2950 EPA method 524.2 | Jan 1, 2025 – Mar 31, 2025 |
|
||
| 66.6 ug/l , sample collected Jan 29, 2025 07:05, sampling point SMH | TTHM 2950 EPA method 524.2 | Jan 1, 2025 – Mar 31, 2025 |
-
- Collected
- Feb 11, 2026 08:45
- Sampling point
- SMT Location withheld
- Sample type
- Routine
- Lab sample
- 810-180722-2
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- 39.1 ug/l
-
- Collected
- Feb 11, 2026 08:30
- Sampling point
- SMH Location withheld
- Sample type
- Routine
- Lab sample
- 810-180722-1
- Laboratory
- Eurofins Eaton Analytical South Bend in
- Monitoring period
- Not recorded
-
TTHM 2950 EPA method 524.2
- Result
- 23 ug/l
-
- Collected
- Oct 16, 2025 09:15
- Sampling point
- SMT Location withheld
- Sample type
- Routine
- Lab sample
- TH-251017-002
- Laboratory
- MSDH Lab
- Monitoring period
- Oct 1, 2025 – Dec 31, 2025
-
TTHM 2950 EPA method 524.2
- Result
- 48.4 ug/l
-
- Collected
- Oct 16, 2025 09:45
- Sampling point
- SMH Location withheld
- Sample type
- Routine
- Lab sample
- TH-251017-001
- Laboratory
- MSDH Lab
- Monitoring period
- Oct 1, 2025 – Dec 31, 2025
-
TTHM 2950 EPA method 524.2
- Result
- 33.1 ug/l
-
- Collected
- Aug 6, 2025 09:55
- Sampling point
- SMT Location withheld
- Sample type
- Routine
- Lab sample
- TH-250807-006
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2025 – Sep 30, 2025
-
TTHM 2950 EPA method 524.2
- Result
- 55 ug/l
-
- Collected
- Aug 6, 2025 09:10
- Sampling point
- SMH Location withheld
- Sample type
- Routine
- Lab sample
- TH-250807-005
- Laboratory
- MSDH Lab
- Monitoring period
- Jul 1, 2025 – Sep 30, 2025
-
TTHM 2950 EPA method 524.2
- Result
- 31.1 ug/l
-
- Collected
- Apr 22, 2025 07:50
- Sampling point
- SMT Location withheld
- Sample type
- Routine
- Lab sample
- TH-250423-012
- Laboratory
- MSDH Lab
- Monitoring period
- Apr 1, 2025 – Jun 30, 2025
-
TTHM 2950 EPA method 524.2
- Result
- 58.7 ug/l
-
- Collected
- Apr 22, 2025 08:20
- Sampling point
- SMH Location withheld
- Sample type
- Routine
- Lab sample
- TH-250423-011
- Laboratory
- MSDH Lab
- Monitoring period
- Apr 1, 2025 – Jun 30, 2025
-
TTHM 2950 EPA method 524.2
- Result
- 25.9 ug/l
-
- Collected
- Jan 29, 2025 07:35
- Sampling point
- SMT Location withheld
- Sample type
- Routine
- Lab sample
- TH-250130-006
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2025 – Mar 31, 2025
-
TTHM 2950 EPA method 524.2
- Result
- 64.6 ug/l
-
- Collected
- Jan 29, 2025 07:05
- Sampling point
- SMH Location withheld
- Sample type
- Routine
- Lab sample
- TH-250130-005
- Laboratory
- MSDH Lab
- Monitoring period
- Jan 1, 2025 – Mar 31, 2025
-
TTHM 2950 EPA method 524.2
- Result
- 66.6 ug/l
Routine (10).