Skip to main content
Alpha

This is a rebuild of Drinking Water Watch and not yet the official record. Use the agency’s current Drinking Water Watch for anything you need to rely on.

Chemical and radiological sample results

MS0360009 , Hurricane Creek Water Assn

23 of the 64 analytes this system has been tested for have been detected at least once, across 393 samples on record.

The other 41 were tested for and never found. An analyte is counted here if any result on record measured it, so this covers the whole history and not the samples listed below.

Across all 393 samples on record, detections range from June 30, 2000 to July 21, 2026. These figures cover the whole record; the list of samples further down is narrowed.

What counts as a non-detect is defined in the help: Less than Indicator. This system’s violations.

What has been detected, ever

Every analyte measured above its reporting level at any point in this system’s record, most often detected first. This is not limited to the samples listed below.

Every analyte ever detected for Hurricane Creek Water Assn, with how many results found it and when it was first and last detected. Covers the whole record, not only the samples listed below.
Analyte Kind Detected in First detected Last detected
Copper, Free 1022 Inorganic Chemical 297 of 298 results Jun 30, 2000 Jun 23, 2025
Lead 1030 Inorganic Chemical 146 of 298 results Jun 30, 2000 Jun 23, 2025
Nitrate-Nitrite 1038 Inorganic Chemical 23 of 23 results May 17, 2004 Feb 9, 2026
Nitrate 1040 Inorganic Chemical 23 of 23 results May 17, 2004 Feb 9, 2026
Barium 1010 Inorganic Chemical 10 of 10 results Sep 29, 2003 Feb 24, 2025
Combined Radium (-226 & -228) 4010 Radionuclide 7 of 7 results Sep 26, 2011 Jul 21, 2026
Radium-228 4030 Radionuclide 7 of 7 results Sep 26, 2011 Jul 21, 2026
Total Haloacetic Acids (Haa5) 2456 Organic Chemical 5 of 21 results Jun 11, 2007 Dec 12, 2022
Radium-226 4020 Radionuclide 4 of 7 results Mar 19, 2012 Jul 21, 2026
TTHM 2950 Organic Chemical 4 of 18 results Jun 11, 2007 Nov 14, 2024
Nickel 1036 Inorganic Chemical 4 of 10 results Sep 29, 2003 Aug 31, 2022
Sodium 1052 Inorganic Chemical 3 of 3 results Sep 12, 2019 Feb 7, 2022
Bromodichloromethane 2943 Organic Chemical 2 of 14 results Nov 14, 2024 Nov 14, 2024
Monobromoacetic Acid 2453 Organic Chemical 2 of 15 results Apr 22, 2019 Jun 15, 2020
Gross Alpha Particle Activity 4109 Radionuclide 2 of 4 results Jun 26, 2012 Sep 10, 2012
Gross Alpha, Excl. Radon & U 4000 Radionuclide 1 of 3 results Jul 21, 2026 Jul 21, 2026
Gross Alpha, Incl. Radon & U 4002 Radionuclide 1 of 3 results Jul 21, 2026 Jul 21, 2026
Chloroform 2941 Organic Chemical 1 of 14 results Nov 14, 2024 Nov 14, 2024
Calcium 1016 Inorganic Chemical 1 of 1 result May 17, 2021 May 17, 2021
Chloride 1017 Inorganic Chemical 1 of 1 result May 17, 2021 May 17, 2021
Conductivity @ 25 C Umhos/CM 1064 Water Quality 1 of 1 result May 17, 2021 May 17, 2021
Monochloroacetic Acid 2450 Organic Chemical 1 of 15 results Apr 22, 2019 Apr 22, 2019
Chromium 1020 Inorganic Chemical 1 of 10 results Apr 13, 2015 Apr 13, 2015

Showing samples collected between September 25, 2024 and September 25, 2026. That is this page’s default, not a limit on what the agency records.

Show every sample on record

Choose a date range

The most recent samples, result by result

The table below lists 1–10 of 18 samples, newest first — collected June 23, 2025 to July 21, 2026. The summary above covers all 18.

33 results from the 10 samples listed here: 13 detected, 20 not detected. Across the whole record it is 547 of 1,150. A sample is analysed for many analytes at once, so one sample appears on as many rows as it had results.

We withheld the location of 7 sampling points below. The location on record identifies a private home, and we do not publish those. That is our decision, not the agency’s. The sampling point, its type and every result taken there are published unchanged.

Chemical and radiological sample results for Hurricane Creek Water Assn, every result from 1 to 10 of 18 samples shown, newest first. Not detected means the amount was below the level the laboratory can reliably report, which is given beside it.
Result Analyte Monitoring period
Collected
Jul 21, 2026 09:00
Sampling point
TF081 Treatment Facility TF081
Sample type
Routine
Lab sample
810-201426-1
Laboratory
Eurofins Eaton Analytical South Bend in
1.66 pci/l , sample collected Jul 21, 2026 09:00, sampling point TF081 Gross Alpha, Excl. Radon & U 4000 Not recorded
1.66 pci/l , sample collected Jul 21, 2026 09:00, sampling point TF081 Gross Alpha, Incl. Radon & U 4002 EPA method 7110B Not recorded
Not detected below 1 ug/l Minimum Reporting Level , sample collected Jul 21, 2026 09:00, sampling point TF081 Combined Uranium 4006 EPA method 200.8 Jul 1, 2026 – Sep 30, 2026
2.09 pci/l The agency recorded which kind of limit this result was below, but stored nothing as the limit itself, which is not a level. The type is published and the value is null. What the limit was is not on record. Whether the result was a detection is a separate column: read resultType. , sample collected Jul 21, 2026 09:00, sampling point TF081 Combined Radium (-226 & -228) 4010 Jul 1, 2026 – Sep 30, 2026
0.27 pci/l , sample collected Jul 21, 2026 09:00, sampling point TF081 Radium-226 4020 EPA method 7500-RAB Not recorded
1.82 pci/l , sample collected Jul 21, 2026 09:00, sampling point TF081 Radium-228 4030 EPA method 7500-RAD Not recorded
Collected
Feb 9, 2026 13:00
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
NI-260210-024
Laboratory
MSDH Lab
0.542 mg/l , sample collected Feb 9, 2026 13:00, sampling point TF080 Nitrate-Nitrite 1038 EPA method QC10107041C Jan 1, 2026 – Dec 31, 2026
0.542 mg/l , sample collected Feb 9, 2026 13:00, sampling point TF080 Nitrate 1040 EPA method QC10107041C Jan 1, 2026 – Dec 31, 2026
Not detected below 0.02 mg/l Minimum Reporting Level , sample collected Feb 9, 2026 13:00, sampling point TF080 Nitrite 1041 EPA method QC10107041C Jan 1, 2026 – Dec 31, 2026
Collected
Nov 17, 2025 02:00
Sampling point
SM2 Location withheld
Sample type
Routine
Lab sample
810-172287-1
Laboratory
Eurofins Eaton Analytical South Bend in
Not detected below 2 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Monochloroacetic Acid 2450 EPA method 552.2 Not recorded
Not detected below 1 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Dichloroacetic Acid 2451 EPA method 552.2 Not recorded
Not detected below 1 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Trichloroacetic Acid 2452 EPA method 552.2 Not recorded
Not detected below 1 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Monobromoacetic Acid 2453 EPA method 552.2 Not recorded
Not detected below 1 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Dibromoacetic Acid 2454 EPA method 552.2 Not recorded
Not detected below 2 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Total Haloacetic Acids (Haa5) 2456 EPA method 552.2 Jan 1, 2025 – Dec 31, 2025
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Chloroform 2941 EPA method 524.2 Not recorded
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Bromoform 2942 EPA method 524.2 Not recorded
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Bromodichloromethane 2943 EPA method 524.2 Not recorded
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 Dibromochloromethane 2944 EPA method 524.2 Not recorded
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Nov 17, 2025 02:00, sampling point SM2 TTHM 2950 EPA method 524.2 Jan 1, 2025 – Dec 31, 2025
Collected
Sep 2, 2025 12:30
Sampling point
TF080 Treatment Plant T080
Sample type
Routine
Lab sample
CN-250903-004
Laboratory
MSDH Lab
Not detected below 0.015 mg/l Minimum Reporting Level , sample collected Sep 2, 2025 12:30, sampling point TF080 Cyanide 1024 EPA method QC10204001X Jan 1, 2023 – Dec 31, 2025
Collected
Jun 23, 2025 06:45
Sampling point
LC018 Location withheld
Sample type
Routine
Lab sample
PB-250624-035
Laboratory
MSDH Lab
0.0036 mg/l , sample collected Jun 23, 2025 06:45, sampling point LC018 Copper, Free 1022 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Jun 23, 2025 06:45, sampling point LC018 Lead 1030 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Collected
Jun 23, 2025 08:15
Sampling point
LC017 Location withheld
Sample type
Routine
Lab sample
PB-250624-034
Laboratory
MSDH Lab
0.0057 mg/l , sample collected Jun 23, 2025 08:15, sampling point LC017 Copper, Free 1022 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Jun 23, 2025 08:15, sampling point LC017 Lead 1030 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Collected
Jun 23, 2025 09:15
Sampling point
LC002 Location withheld
Sample type
Routine
Lab sample
PB-250624-033
Laboratory
MSDH Lab
0.0039 mg/l , sample collected Jun 23, 2025 09:15, sampling point LC002 Copper, Free 1022 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Jun 23, 2025 09:15, sampling point LC002 Lead 1030 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Collected
Jun 23, 2025 08:30
Sampling point
LC031 Location withheld
Sample type
Routine
Lab sample
PB-250624-032
Laboratory
MSDH Lab
0.0709 mg/l , sample collected Jun 23, 2025 08:30, sampling point LC031 Copper, Free 1022 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Jun 23, 2025 08:30, sampling point LC031 Lead 1030 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Collected
Jun 23, 2025 08:15
Sampling point
LC005 Location withheld
Sample type
Routine
Lab sample
PB-250624-031
Laboratory
MSDH Lab
0.0372 mg/l , sample collected Jun 23, 2025 08:15, sampling point LC005 Copper, Free 1022 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Jun 23, 2025 08:15, sampling point LC005 Lead 1030 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Collected
Jun 23, 2025 09:45
Sampling point
LC024 Location withheld
Sample type
Routine
Lab sample
PB-250624-040
Laboratory
MSDH Lab
0.0015 mg/l , sample collected Jun 23, 2025 09:45, sampling point LC024 Copper, Free 1022 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025
Not detected below 0.5 ug/l Minimum Reporting Level , sample collected Jun 23, 2025 09:45, sampling point LC024 Lead 1030 EPA method 200.8 Jan 1, 2023 – Dec 31, 2025

Routine (10).